IN/OUT Jumper (JU3) - When a card is presented and access is granted, this determines whether the
IEI Door Control Module records the transaction as IN or OUT.
On both pins = OUT On one pin only = IN
Wiegand Interface Module LEDs
LED 3: This is a bicolor LED that emulates the relay state of the IEI Door Control Module (Red = De-energized;
Green = Energized)
LED 2: This is an amber LED that emulates the yellow LED of the IEI Door Control Module (Program Mode, Card
Presentation)
LED 1: This is a red LED that blinks when data is received from the Weigand reader. It also indicates errors using the
following flash patterns:
1 Flash: Communication error - The Wiegand Interface Module did not receive all of the Wiegand data
from the reader. Check the connections between the Wiegand Interface Module and the reader.
BE SURE TO USE SHIELDED CABLE BETWEEN THESE UNITS.
2 Flashes: Parity Error - This occurs when the parity of the Wiegand data is incorrect.
3 Flashes: Incorrect Site Code - This occurs when the Site Code contained in the 26-bit Wiegand data does
not match the Site Code set on Dip Switches 1 - 8 (This error only occurs when Dip Switch 9 set
to on).
4 Flashes: Overflow Error - This error occurs when the Wiegand data sent to the Wiegand Interface Module
contains more than 26 bits.
If you have any questions concerning the Installation, Application or Operation of this device please call the IEI
Technical Support Line at 1-800-343-9502.