Owner's Manual

# NAME
DESCRIPTION
1 24 VAC
Provides maximum 10 VA auxiliary
power for accessories.
2 24 VAC
Provides maximum 10 VA auxiliary
power for accessories.
3 ALTERNATE
Momentary input, must be released
and re-entered to be recognized.
This input is used for “COMMAND OPEN/COMMAND
CLOSE” applications. The 1st signal will cause the gate to
begin opening. A 2nd signal received during the open cycle
will stop the gate immediately. A 3rd signal will close the gate.
Connect appropriate access control devices to this terminal
and #0 or #16 COMMON.
4 RADIO OPEN
Momentary input, must be released
and re-entered to be recognized.
Once activated the gate will open fully. Activation while the
gate is closing will cause it to re-open.
5 FREE EXIT
Momentary or continuous input.
Once activated the gate will open fully. Activation while the
gate is closing will cause it to re-open. Continuous activation
while the gate is open will prevent the Timer-To-Close function
from automatically closing the gate.
6 OPEN
Momentary or continuous signal. On/
Off mode set by Switch #1
Once activated the gate will open fully. Activation while the
gate is closing will cause it to re-open. Continuous activation
while the gate is open will prevent the Timer-To-Close function
from automatically closing the gate. Continuous signal
required to move the gate when in the alarm mode.
7 CLOSE
Momentary or continuous signal. On/
Off mode set by Switch #1
Once activated the gate will close fully. Activation while the
gate is opening has no effect. Continuous signal required to
move the gate when in the alarm mode.
8 STOP Momentary or continuous signal.
Overrides all other signals. Once activated, the gate will
immediately stop and await a new command. If the STOP
input is continuously activated, the gate will not move.
9 OPEN PHOTO Momentary or continuous signal.
This input is active only when referenced to the opening
direction, it has no effect on the gate when closing or about to
close. If activated when the gate is opening the gate will stop,
pause and reverse in the close direction for 1/2 second
(approx. 2 inches) and stop. Continuous activation will
prevent the gate from moving in the open direction. When the
input is removed normal operation is resumed. This input is
intended for photoelectric eye systems and other non-contact
devices as appropriate. Connect here and to terminal #16
COMMON. Multiple devices may be connected in parallel.
TERMINAL STRIP REFERENCE CHART
# NAME
DESCRIPTION
10 CLOSE PHOTO
Momentary or continuous signal.
This input is active only when referenced to the closing
direction, it has no effect on the gate when opening or about to
open. If activated when the gate is closing the gate will stop,
pause and reverse in the open direction for 1/2 second
(approx. 2 inches) and stop. Continuous activation will
prevent the gate from moving in the close direction. When the
input is removed normal operation is resumed. Continuous
activation while the gate is open will prevent the Timer-To-
Close function (if enabled) from automatically closing the gate.
This input is intended for photoelectric eye systems and other
non-contact devices as appropriate. Connect here and to
terminal #16 COMMON. Multiple devices may be connected
in parallel.
11 REV LOOP
Momentary or continuous signal.
This input is active only when the gate is closing or when it’s
fully open and the Close Timer is operative. All stand-alone
vehicle detectors, photo-eyes and active edges should be
connected here and to terminals #3 or #13 COMMON.
Multiple devices may be connected in parallel.
12 OPEN EDGE
Momentary or continuous signal.
This input is active only when referenced to the opening
direction, it has no effect on the gate when closing or about to
close. If activated when the gate is opening the gate will stop,
pause and reverse in the close direction for 1/2 second
(approx. 2 inches) and stop. Continuous activation will prevent
the gate from moving in the open direction. If a second
activation occurs before the limit switch is activated the gate
will stop and a require a renewed, intended input to move in
the open direction and before an automatic activation device
(timer, etc.) will operate. This input is intended for Electric
Gate Edge systems and other minimum-contact devices as
appropriate. Connect here and to terminal #16 COMMON.
Multiple devices may be connected in parallel.
13 CLOSE EDGE
Momentary or continuous signal.
This input is active only when referenced to the closing
direction, it has no effect on the gate when opening or about to
open. If activated when the gate is closing the gate will stop,
pause and reverse in the open direction for 1/2 second
(approx. 2 inches) and stop. Continuous activation will
prevent the gate from moving in the close direction.
Continuous activation while the gate is open will prevent the
Timer-To-Close function (if enabled) from automatically
closing the gate. If a second activation occurs before the limit
switch is activated the gate will stop and a require a renewed,
intended input to move in the close direction and before an
automatic activation device (timer, etc.) will operate. This input
is intended for Electric Gate Edge systems and other
minimum-contact devices as appropriate. Connect here and
to terminal #16 COMMON. Multiple devices may be
connected in parallel.
Terminal Strip Reference Chart continued on next page
D: STARTING THE OPERATOR
19