Owner's Manual

motor wire is on the capacitor terminal post with the BLUE wire
from the high voltage wire harness AND
the BLUE motor wire is
on the capacitor terminal post with the RED wire from the high
voltage wire harness. The high voltage wire harness is now
configured for left-hand operation. Left-hand conversion is now
complete.
Locate the limit switches as shown in Figure 19. As shipped from
the factory the switches are wired for right hand operation (red/
white on the lower switch and yellow/white on the upper switch).
To reconfigure the limit switches for left hand operation reroute
the yellow wire to the lower switch and the red wire to the upper
switch. The limit switches are now configured for left-hand
operation.
MOUNTING THE LIMIT CAMS
Before turning on the main power, the limit cams must be mounted
to the chain in their approximate positions. See Figures 19 and 20.
Figure 19 illustrates a view of the RSX1000 Control Box/
Mechanical Unit that faces the gate which depicts the Output Drive
Sprocket components.
Figure 20 shows how to install the Limit
Cams to the chain. NOTE: IT IS
IMPORTANT TO INSTALL THE
CAMS AROUND THE WHOLE
LINK AS ILLUSTRATED AND
WITH THE STUD/NUT IN THE
PROPER ORIENTATION AS
OUTLINED IN THE FOLLOWING
PARAGRAPHS.
Manually push the gate all the way
open. As depicted in Figure 19 locate
and mark with chalk the proper chain
link (depending on Right-Hand or Left-
Hand operation) for OPEN Limit
operation.
Manually push the gate all the way closed. Following the
procedure shown in Figure 20, mount the Limit Cam on the chain
link that was marked with chalk in the previous step, the link
should now be parallel with the ground and approximately 4 to 5
feet from the end of the gate. The cam MUST BE mounted such
that the lobe is DOWN (TOWARD THE GROUND).
NOTE: IF RIGHT-HAND OPERATION (STANDARD)
MOUNT THE CAM WITH THE STUD/NUT POINTING AT
THE GATE, IF LEFT-HAND OPERATION MOUNT THE
CAM WITH THE STUD/NUT POINTING AWAY FROM THE
GATE.
As depicted in Figure 19 locate and mark with chalk the proper
chain link (depending on Right-Hand or Left-Hand operation) for
CLOSE Limit operation.
At this time recheck the Toggle Limit Switch ACTUATORS for
proper positioning to accept the limit cams. See Figure 19.
Manually push the gate all the way open again. Following the
procedure shown in Figure 20, mount the Limit Cam on the chain
link that was marked with chalk in the previous step, the link
should now be parallel with the ground and approximately 4 to 5
feet from the end of the gate. The cam MUST BE mounted such
that the lobe is DOWN (TOWARD THE GROUND).
NOTE: IF RIGHT-HAND OPERATION (STANDARD)
MOUNT THE CAM WITH THE STUD/NUT POINTING
AWAY FROM THE GATE, IF LEFT-HAND OPERATION
MOUNT THE CAM WITH THE STUD/NUT POINTING AT
THE GATE.
NOTE: ENSURE THAT WHEN THE CAMS ENTER THE
LOWER IDLER SPROCKETS THEY ARE ORIENTED
PROPERLY AS FOLLOWS: WHEN THE CAM ROUNDS
THE INSIDE SPROCKET (CLOSEST TO THE PEDESTAL)
ITS STUD/NUT SHOULD BE POINTING TOWARDS THE
PEDESTAL, WHEN THE CAM ROUNDS THE OUTSIDE
SPROCKET (FARTHEST FROM THE PEDESTAL) ITS
STUD/NUT SHOULD BE POINTING AWAY FROM THE
PEDESTAL.
The limit cams are now roughly adjusted. If the gate should stop
short of fully opened or closed, or if it bangs against the end stops
during operation, the limit cams can be fine-tuned after the
operator is powered up. (See FINAL SETTING OF THE LIMIT
CAMS, page 18)
RED/WHITE-LEFT HAND
LIMIT SWITCH WIRING
YELLOW/WHITE-RIGHT HAND
LIMIT CAMS.
AS SHOWN TO ACCEPT
ACTUATORS ARE SET
ENSURE LIMIT SWITCH
OPENED (LEFT-HAND)
CLOSED (RIGHT-HAND)
MARK THIS CHAIN LINK:
WHEN FULLY ______
RED/WHITE-RIGHT HAND
Y
ELLOW/WHITE-LEFT HAND
POINT DOWN
CAMS LOBES
ENSURE LIMIT
LIMIT SWITCH WIRING
CLOSED (LEFT-HAND)
OPENED (RIGHT-HAND)
WHEN FULLY ______
MARK THIS CHAIN LINK:
110501 REV B
Figure 19: Limit Cam Mounting & Limit Switch Wiring
Figure 20: Mounting
Limit Cams to Chain
110501A2
RISK OF ELECTROCUTION
DO NOT BEGIN TO SET OR RESET THE
FOLLOWING ADJUSTMENTS UNTIL THE POWER
IS TURNED OFF AT THE MAIN POWER SWITCH
WARNING!
C: INSTALLING THE OPERATOR
16