Owner's Manual

PERS-4200 System Functions
Copyright © 2012 Linear LLC 232523 B
Activity Timer
Testing Sensors
Testing Log
Remote Call-in Speakerphone Mode
Sensor Fault Conditions
Service Information
Reminder Messages
System Connections
Limited Warranty
Speakerphone Mode
Adding One Sensor
Important Installation Warnings
The Console can check for lack of daily activity and
automatically call the monitoring service.
(This is an option and may not be active on your system.)
WHEN THE ACTIVITY TIMER IS RUNNING
1
2
3
The green
Home
indicator will blink, showing that
the activity timer is running. This signals you that it is
time to press the
Home
button.
When less than 15 minutes remain on the activity
timer, the green
Home
indicator will flash and the
Console announces "Activity Window Expiring" every
3 minutes.
You need to press the
Home
button or
trigger an activity sensor
before
the
timer expires to prevent an inactivity call
to the monitoring service.
WHEN THE ACTIVITY TIMER IS RUNNING OUT OF TIME
RESETTING THE ACTIVITY TIMER TO PREVENT A CALL
Your monitoring service will set the
time(s) of day that you will need to
press the
Home
button.
Pressing the
Home
button again will cause the
Console to announce the time, current Console
mode, and and trouble conditions. (Optional)
It's important to test your system weekly
or when the automatic test reminder message plays.
TESTING FROM A PORTABLE SENSOR
1
Press a portable sensor's button until the Console
announces "Emergency call being placed".
CAUTION: BEFORE TESTING YOURSELF, CALL THE MONITORING
SERVICE TO NOTIFY THEM THAT YOU WILL BE TESTING
Testing should be done from all portable sensors and the Console.
2
The
HELP
button will blink red and the Console will repeat
the announcement every 30 seconds until the message is
reported to the monitoring service then the Console will
announce "Emergency reported, p
lease stand by".
3
Follow the instructions from the monitoring service dispatcher.
TESTING FROM THE CONSOLE
1
Press the Console's
HELP
button until the Console
announces "Emergency call being placed".
2
The
HELP
button will blink red and the Console will repeat
the announcement every 30 seconds until the message is
reported to the monitoring service then the Console will
announce "Emergency reported, p
lease stand by".
3
Follow the instructions from the monitoring service dispatcher.
Emergency sensors can be added
to the Console
one at a time using these steps:
TO ADD A SENSOR
1
Press the Cancel button for 5 seconds.
2
The Console will announce "Ready to
learn sensor, Zone [zone number 1-16]".
3
Activate the sensor by pressing its button.
WARNING: THE CONSOLE WILL NOT BE ABLE TO REPORT
AN EMERGENCY WHILE ADDING A SENSOR
New Sensor
4
The Console will announce "[Sensor type] sensor learned".
5
After the sensor has been added, the Console will resume
normal operation and announce "Console ready".
NOTE:
In case you need to exit at Step 3 without
adding a sensor, press the
Cancel
button.
Sensors update the Console with their status.
(Status announcements will not sound while the Console is in Night Mode.)
SENSOR STATUS REPORTS
1
NOTE:
Status reports are
not monitored while the
Console is in Away Mode
Sensors can be set by the monitoring service to regulary send their
status to the Console. The regular status signals verify that the sensor
is working properly. The length of time that missing st
atus signals from
a sensor cause a fault report is set by the monitoring service.
SENSOR LOW BATTERIES
2
If the Console has not received status signals from a sensor,
the yellow
Cancel
indicator will light and a report will be
sent to the monitoring service. The Console may also be
setup to announce the sensor trouble.
Press the
Cancel
button to silence the announcement and
clear the indication.
Sensors are powered by batteries. Each sensor automatically
checks its battery and if the battery is low the sensor will send a
low battery signal to the Console.
1
2
If the Console receives a low battery signal from a sensor,
the yellow
Cancel
indicator will blink and a report will be
sent to the monitoring service. The Console may also be
setup to announce the sensor trouble.
Press the
Cancel
button to silence the announcement and
clear the indication.
For service, refer to the information below.
Your Monitoring Conpany:
Your telephone
(
optional connection)
24-hour power outlet
(an outlet that's not
controlled by a wall switch)
(Your monitoring service will typically make these connections.)
Your telephone
wall jack
The Console connects to power and the telephone.
PERS
Console
Must be connected
at all times *
NOTE: The local telephone or any
device connected to the console's
phone jack will be disconnected from
the telephone line while the console
is reporting to the central station
The Console can be used as a speakerphone.
(This is an option and may not be active on your system.)
1
While the telephone is ringing, activating an
emergency pendant or pressing the Console's
HELP
button will answer the telephone.
NOTE: Speakerphone Mode can only be used on incoming calls and will not function
when the Console is operating from battery backup power. Attempting to answer
while the Console is on backup power
will cause an emergency alarm.
WARNING: THE CONSOLE WILL NOT BE ABLE TO REPORT
AN EMERGENCY WHILE THE SPEAKERPHONE IS ACTIVE
2
You can talk to the caller using the Console as a speakerphone. The
HELP
button will light
orange while the speakerphone is on.
3
When your call is finished, press the
HELP
button or press a pendant button to hang up the
telephone. (The Console has a timer that will end the call automatically after a preset time.)
NOTE: TO REPORT AN EMERGENCY WHEN THE SPEAKERPHONE IS IN USE, PRESS EITHER THE
HELP BUTTON OR A PENDANT BUTTON TO END THE PHONE CALL AND THEN PRESS ONE OF
THESE BUTTONS AGAIN TO REPORT THE EMERGENCY.
Automatic Speakerphone Mode can be started by a caller.
(This is an option and may not be active on your system.)
1
WARNING: THE CONSOLE WILL NOT BE ABLE TO REPORT
AN EMERGENCY WHILE THE SPEAKERPHONE IS ACTIVE
Call the Console's telephone number, let it ring three times, then hang up.
NOTE: TO REPORT AN EMERGENCY WHEN THE SPEAKERPHONE IS IN USE, PRESS EITHER THE
HELP BUTTON OR A PENDANT BUTTON TO END THE PHONE CALL AND THEN PRESS ONE OF
THESE BUTTONS AGAIN TO REPORT THE EMERGENCY.
2
Wait about 10 seconds, then call the Console a second time.
3
4
5
Have a conversation through the Console's speaker and microphone.
When the call is finished, press "9" to disconnect. (In case you forget to
disconnect, the Console has a timer that will end the call automati
cally after
a preset time, warning beeps will sound 5 seconds prior to disconnect.)
When the Console answers, a tone will sound for 8 seconds. When
the tone ends enter the 4-digit password (1-2-3-4) or _____ followed
by the "#" key. (You have 30 seconds to enter the password.)
NOTE:
During the call, the caller can use the "1" and "3" keys on the telephone to
switch from the automatic 2-way voice mode to manual control of the call direction
(in case a loud room noise near the Console is preventing hearing the caller). Press
"1" to talk, press "3" to listen. Press "8" to return to automatic 2-way voice mode.
During manual control, the Console will disconnect after 90 seconds if no keys are
pressed (warning beeps will sound 5 seconds prior to the disconnect).
1
When a reminder message plays, you will hear it from the Console's speaker.
The Console can announce messages to remind you of important events.
(This is an option and may not be active on your system.)
The Console can announce five different messages at preset dates and times. The messages,
message options, and the times they will play are set by your monitoring service. The pre-recorded
messages that the Consol
e can play are:
2
The message can be set to repeat its announcement until it is
cleared. It can repeat every 3 minutes for 15 or 30 minutes.
3
Most reminder messages are cleared by pressing the
Cancel
button. The system test message requires you to
press your portable personal help button on your pendant or
wristband sensor, then the monitoring service will confirm the
test with you ov
er the Console's speaker.
4
If a reminder message is not cleared, a report can be sent
to the monitoring service so they can check up on you.
"Attention, it is time to test your PERS. Please press your personal help button"
"Attention, it is time to take your medication. Please press the
Cancel
button"
"Attention, your ride will be here at [hour & minute AM/PM]. Please press the
Cancel
button"
"Attention, your appointment is at [hour & minute AM/PM]. Please press the
Cancel
button"
"Attention, alarm reminder. Please press the
Cancel
button"
NOTE:
Reminder messages will not play when the Console
is in Away Mode
• Be sure and test your system weekly.
Do not bring any electrical appliances or electrical
noise generating devices (fl uorescent lamps,
motors, etc.) near the Console.
Do not use ammonia, benzene, thinner, or similar
solvents, or abrasive powder to clean the housing
of the Console or Pendant. Clean by wiping with a
damp, soft cloth.
The Console should be kept free of dust and
moisture.
The Console should not be located where direct
sunlight will shine on it.
Avoid locating the Console in extremely hot or cold
locations.
___________ ___________ ___________
___________ ___________ ___________
___________ ___________ ___________
___________ ___________ ___________
___________ ___________ ___________
___________ ___________ ___________
___________ ___________ ___________
___________ ___________ ___________
___________ ___________ ___________
Each time the system is tested, write down the date.
This Linear product is warranted against defects in material and workmanship for twelve (12) months. This warranty
extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels.
Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the
nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for
consequential damages arising out of or in connection with use or performance of this product or other
indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or
reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for
tness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties
express or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear
Technical Services at 1-800-421-1587 for an RPA# and other important details.
Important Wireless Information
Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling.
However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15
devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals
that occur on or near their operating frequencies, regardless of code settings.
Changes or modifi cations to the device may void FCC compliance.
• Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or
dealer, and these facts should be communicated to the ultimate users.
PRINTER’S INSTRUCTIONS:
INSTR,PERS-4200,QUICK GUIDE,ENGLISH; LINEAR P/N: 232523 B; INK: 4/C PROCESS; MATERIAL: 20# WHITE COATED; SIZE: 11.000” x 17.000”; FOLDING: 1-FOLD VERTICAL, FINISH 8.500” X 11.000”; SCALE: 1-1; SIDE 2 OF 2