Owner's Manual

OPERATION & ADJUSTMENT INSTRUCTIONS
NOTE: It is now necessary to turn on the power
in order to run the Opener to check for proper
operation and limit settings. Before doing so, ensure
that all mounting hardware are installed and properly
tightened, that all electrical connections are per local code
requirements, and that proper wiring practices have been
followed.
Also, double-check that all ropes have
been removed from the door and that the doorway
is clear.
MOMENTARY CONTACT: Button can be pushed and then released and door will keep moving or stop without
maintaining pressure on the button.
CONSTANT PRESSURE: Constant pressure is required on the button in order for continued door movement. When
the button is released the door will stop and possibly reverse to full open depending on wiring type.
DOOR EDGE/PHOTOELECTRIC INPUT: The operator wiring provides for input from an optional pneumatic or
electric door bottom edge or photoelectric device that will cause a closing door to stop and may reverse it to open
depending on the wiring type.
OPEN OVERRIDE: When the door is closing a momentary push of the OPEN button will reverse the door to open.
WIRING TERMS
TO REDUCE THE RISK OF SEVERE INJURY OR
DEATH: READ AND FOLLOW ALL INSTRUCTIONS!
WARNING
FAILURE TO TEST REVERSING SYSTEM
COULD RESULT IN DEATH OR SERIOUS
INJURY. TEST THIS SYSTEM ONCE A MONTH.
WARNING
14