Owner's Manual
MOTOR CONTROL BOARD TERMINAL BLOCK REFERENCE CHART (CONT.)
NAME
DESCRIPTION
CLO
CLOSE 3BS
When activated a gate that is stopped will move close; a gate
that is opening will continue to move open; a gate that is closing
will continue to move close. Continuous signal required to move
the gate when in the alarm mode. See also the section on
Switch Options and Functions for alternate operation. Connect
appropriate access control devices to this terminal and COM
(Common). Typically used with a three button station (3BS).
OPN
OPEN 3BS
When activated, a gate that is stopped will move open; a gate
that is moving close will stop, pause and move open; a gate that
is moving open will continue to continue to move open.
Continuous signal required to move the gate when in the alarm
mode. See also the section on Switch Options and Functions
for alternate operation. Connect appropriate access control
devices to this terminal and COM (Common). Typically used
with a three button station (3BS).
STO
STOP 3BS
When activated, a get that is stopped will remain stopped; a
gate that is moving will stop. As long as this input is activated
the gate will not respond to any other command. This input is
active during an alarm mode. Connect appropriate access
control devices to this terminal and COM (Common). Typically
used with a three button station (3BS).
OPN PHO
OPEN NON-CONTACT SENSOR
When activated, a gate is moving open will stop; a gate that is
moving close will continue to move close; a gate that is stopped
will not move open until the input becomes inactive.
Continuous activation will prevent the gate from moving in the
open direction. When the input is removed a gate that was
moving open prior to activation will resume moving in the open
direction. This input is intended for photoelectric eye systems
and other non-contact devices as appropriate. Connect here
and to COM (Common). Multiple devices may be connected in
parallel.
CLO PHO
CLOSE NON-CONTACT SENSOR
When activated, a gate is moving close will stop, pause and
reverse open for 2 seconds; a gate that is moving open will
continue to move open; a gate that is stopped will not move
close until the input becomes inactive. Continuous activation
will prevent the gate from moving in the close direction. When
the input is removed a gate that was moving close prior to
activation will resume moving in the close direction. This input
is intended for photoelectric eye systems and other non-contact
devices as appropriate. Connect here and to COM (Common).
Multiple devices may be connected in parallel.
NAME
DESCRIPTION
SHW
SHADOW LOOP
REV
REVERSING LOOP
When activated, a gate that is moving close will stop, pause and
reverse open; a gate that is moving open will continue to move
open; a gate that is stopped will not move close until this input is
inactive. The output from the pre-installed Reverse Loop socket
is pre-wired to this terminal. Connect appropriate devices to this
terminal and COM (Common). Typically used with a Vehicular
Loop Detectors.
OPN EDG
OPEN CONTACT SENSOR
When activated, a gate that is moving open will stop, pause and
reverse close for 2 seconds; a gate that is moving close will
continue to move close; a gate that is stopped will not move open
until this input is inactive. The first activation of this input while
the gate is moving open will disable the auto reclose function.
Connect appropriate devices to this terminal and COM
(Common). Typically used with Pressure Sensitive Edge
devices.
CLO EDG
CLOSE CONTACT SENSOR
When activated, a gate that is moving close will stop, pause and
reverse open for 2 seconds; a gate that is moving open will
continue to move open; a gate that is stopped will not move close
until this input is inactive. A gate that was moving close prior to
the first activation of this input will resume moving close after this
input becomes inactive. The second activation of this input while
the gate is moving close will disable the auto reclose function.
Connect appropriate devices to this terminal and COM
(Common). Typically used with Pressure Sensitive Edge
devices.
MST OPN
MASTER TO SLAVE “OPEN”
This terminal connection is used for Master/Slave (Primary/
Secondary) installations. This output is connected via a wire to
the Open (OPN) input of the slave (secondary) gate. This is used
to command the slave gate to open.
MST CLO
MASTER TO SLAVE “CLOSE”
This terminal connection is used for Master/Slave (Primary/
Secondary) installations. This output is connected via a wire to
the Close (CLO) input of the slave (secondary) gate. This is used
to command the slave gate to close.
When activated, a gate that is stopped at the Open Limit will not
move close until this input is inactive. Connect appropriate
devices to this terminal and COM (Common). Typically used with
a Vehicular Loop Detectors.
D: STARTING THE OPERATOR