Owner's Manual

NAME
DESCRIPTION
RDO OPN
RADIO OPEN
When activated, a gate that is stopped will move open; a gate
that is moving close will stop, pause and move open; a gate that
is moving open will continue to continue to move open. This
input is ignored during an alarm mode and will not operate the
gate. Connect appropriate access control devices to this terminal
and COM (Common).
CRO
RADIO OPEN/CLOSE
When activated, a gate that is stopped will move open; a gate
that is moving close will stop, pause and move open; a gate that
is moving open will stop; a gate that is stopped at the open limit
will move close, a gate that is stopped at the mid position limit (if
applicable) will move open. This input is ignored during an alarm
mode and will not operate the gate. Connect appropriate access
control devices to this terminal and COM (Common).
FRE
FREE EXIT LOOP
Momentary input, must be released and re-entered to be
recognized. When activated, a gate that is stopped will move
open; a gate that is moving close will stop, pause and move
open; a gate that is moving open will continue to continue to
move open. This input is ignored during an alarm mode and will
not operate the gate. The output from the pre-installed FE loop
socket is pre-wired to this terminal. Connect appropriate access
control devices to this terminal and COM (Common). Preferred
terminal for most HOLD OPEN functions.
NAME
DESCRIPTION
COM
COMMON
Common connection for low voltage signal inputs and 24 Volt
AC power. Three (3) terminals on the left, right, and center of
the motor control board.
24V AC
24 VAC
Provides maximum 10 VA auxiliary power for accessories.
Connect one power lead from an auxiliary device to 24V AC
and one power lead to a common terminal.
24V AC
24 VAC
Provides maximum 10 VA auxiliary power for accessories.
Connect one power lead from an auxiliary device to 24V AC
and one power lead to a common terminal.
ALT
ONE BUTTON CONTROL
Momentary input, must be released and re-entered to be
recognized. When activated, a gate that is moving will stop; a
gate that is stopped will begin moving in the opposite direction
of the previous direction of travel. This input is ignored during
an alarm mode and will not operate the gate. Connect
appropriate access control devices to this terminal and COM
(Common).
MOTOR CONTROL BOARD TERMINAL BLOCK REFERENCE CHART
ORG
BOARD
CIRCUIT
CONTROL
MOTOR
7
RED
WHT
ORG
RED
YEL
7632154
YEL
HARNESS
CONNECTION
BLK
45123 67
BLU
RED
GRY
ORG
WHT
CONNECTION
HARNESS
7
RDO OPN
ALT
24 VAC
24 VAC
COM
{
COM
CRO
FRE
OPN
CLO
STO
COM
COM 3BS
STOP 3BS
CLOSE 3BS
OPEN 3BS
FREE EXIT LOOP
RADIO "OPEN/CLOSE"
COMMONS FOR
AUX. EQUIPMENT
USE
24 VAC
FOR AUX. USE
ONE BUTTON CONTROL
RADIO "OPEN"
COM
{
COM
MST CLO
MST OPN
CLO EDG
OPN EDG
REV
SHW
COM
COM
COM
COM
OPN PHO
CLO PHO
{
{
AUX. USE
CONTROLS AND
COMMONS FOR
MASTER TO SLAVE "CLOSE"
MASTER TO SLAVE "OPEN"
"CLOSE" CONTACT SENSOR
"OPEN" CONTACT SENSOR
REVERSE LOOP
SHADOW LOOP
"CLOSE" NON-CONTACT SENSOR
"OPEN" NON-CONTACT SENSOR
COMMONS FOR AUX.
EQUIPMENT USE
Figure 23:
MCB Terminal
Block
D: STARTING THE OPERATOR