Owner's Manual

TO REDUCE THE RISK OF SEVERE INJURY
OR DEATH: READ AND FOLLOW ALL
INSTALLATION INSTRUCTIONS!
WARNING
Install only on a properly balanced garage
door. An improperly balanced door could
cause severe injury. Have a qualified service
person make repairs to cables, spring
assemblies and other hardware before
installing the opener.
Remove all ropes and remove or make
inoperative all locks (unless mechanically and/
or electrically interlocked to the power unit)
that are connected to the garage door before
installing the opener.
Lightweight doors (fiberglass, aluminum
etc.) must be reinforced to avoid door damage.
Check the door manufacturer’s instruction
manual for a bracing procedure or the
availability or a Reinforcement Kit.
Allstar Models J and H are Commercial
Vehicular Door Operators and as such are
NOT recommended for pedestrian traffic. In
installations where it is known that
pedestrians will be nearby ensure a pedestrian
door is available for entrance and exit to the
building. In addition YOU MUST install an
auxiliary entrapment protection device
(reversing door edge or photoelectric beam
device) as part of the compete operator
system.
Connect an auxiliary entrapment
protection device (reversing edge or
photoelectric device across the door opening).
A device of this type is STRONGLY
ADVISED FOR ALL commercial operator
installations. An auxiliary entrapment
protection device is REQUIRED when the
three button control station is out of sight of
the door or any other automatic or manual
control is used.
Install the opener at least 8 feet or more
above the floor.
Do not connect the opener to the source
of power until instructed to do so.
Locate the control station:
a) within sight of the door and;
b) at a minimum height of five feet
above the floor and;
c) away from all moving parts of the
door.
Do not overtighten the clutch adjustment
to compensate for a poorly working door.
Securely attach any WARNING signs or
placards to either the door or above the
control station as directed (see page 11).
After installing the opener, all safety
features must be tested for proper operation
(see page 16).
COMPONENT IDENTIFICATION LISTING
ITEM PART # DESCRIPTION QTY ITEM PART # DESCRIPTION QTY
1 Per Model Operator Power Head 1 8 009149 Release Chain AR
2 005031 3 Button St ation 1 9 100315 #3 Hand Chain - Precut to 26 FT AR
3 105270 24 Tooth, #50 Chain Sprocket (Standard) 1 10 105349 #50 Drive Chain - 6 FT Long 1
4 105268 12 Tooth, #50 Chain Sprocket (Standard) 1 11 105351 #50 Chain Connecting Link 1
5 105193 Release/Hand Chain Wall Bracket 1
6 100413 1/4” Square Key 2
AR - AS REQUIRED
7 006119 5/16-18 x 1 Square Head Set Screw 4
IMPORTANT INSTALLATION NOTES