Owner's Manual

International Electronics Incorporated Technical/Sales: 1-800-343-9502 , 1-800-733-9502
427 Turnpike Street Phone: 781-821-5566
Canton, Massachusetts 02021 Fax: 781-821-4443
Fax Information Center: 781-821-0734 www.ieib.com
HubPlus Kit Installation Manual
Part# 6065035 rev. 1.1
Fax Document Number: 5035
7
HUB CONNECTION BOARD LAYOUTHUB CONNECTION BOARD LAYOUT
From Hub Plus To Exterior Devices
Alarm Shunt Alarm Shunt Relay Terminals
Connection
Forced Door
Connection Forced Door Relay Terminals
Door Ajar Door Ajar Relay Terminals
Connection
Normally Open Request to Exit
Switch
Input Loop
(includes momentary button for testing)
Connection
Normally Closed Door Position
Switch
(includes jumper to short closed if not used)
Earth Ground Terminal Earth Ground Terminal
LED7
Hub Plus and
Front End Front End Reader Terminals
Power
Indicator
Port C Connection
with Com Line Port C Terminals
Protection
Port A Connection
with Com Line Port A Terminals
Protection
Port A (AUX) Modular Connector for 4 Conductor