Owner's Manual

International Electronics Incorporated Technical/Sales: 1-800-343-9502 , 1-800-733-9502
427 Turnpike Street Phone: 781-821-5566
Canton, Massachusetts 02021 Fax: 781-821-4443
Fax Information Center: 781-821-0734 www.ieib.com
HubPlus Kit Installation Manual
Part# 6065035 rev. 1.1
Fax Document Number: 5035
2
q Step 1: Unpacking the device and checking the packing list.
Open the box. Inside is a metal enclosure. Mounted in the door of the enclosure is a Hub Plus
Controller. Open the metal enclosure and take inventory. Inside the metal enclosure you will find:
1 Hub Plus Controller mounted in door of enclosure
1 Hub Connection Board (mounted)
1 IEI Door Gard Power Supply 12 Volt 1 Amp (mounted)
1 16.5VAC Transformer
1 Camlock
6 Three-Conductor Wire Harnesses (connected between Hub Plus and Hub Connection Board)
1 Four-Conductor Wire Harnesses (connected between Hub Plus and Hub Connection Board)
1 Four-Conductor Cable (connected between Hub Plus and Power Supply)
1 Set of Battery Cables and Hardware Packs
Secured Series Hub Plus Features, Programming, Wiring Guide
Secured Series Hub Plus Kit Installation Manual
Enclosure Dimensions (11.5”w x 11.5”h x 4”d)
Please check the contents of the enclosure and verify all components on the packing list are present.
Taking this inventory will familiarize you with the components as well as ensure you
have a complete kit.
Hub Connection Board
Hub Plus Controller
Power Supply
Wire the lock here!
q Step 2: Connecting the Front End Reader to the Hub Connection Board.
The Hub Plus Kit should be mounted on the secured side of the door and is not meant to be used as an access
device. That is to say that no one should be using the keypad of the Hub Plus as a means of gaining access or
egress. The devices to be used at the door to gain access are Front End Readers (not included). There is an
explanation of what these units are in the Hub Plus Features Programming and Wiring Guide which is found in the
white cardboard box along with the Hub Plus. Whichever Secured Series Front End Reader(s) (you may wire two
Front End Readers in parallel at the door) you choose appropriate for your application it will be connected to Hub
Connection Board. On the Hub Connection Board you will see four screws in the section labeled Front End. Each
of these screws is labeled with a color and they will connect to the corresponding color of the four-conductor wire
harness that is included with the Front End Reader. The connection is made with four-conductor stranded with