Door (Cont.)
Door Status Alarm Output
Sets the actions of a door contact on the door. The door contact must be enabled to use these functions.
1. Check Forced Door to trigger the door
alarm output if the door opens, but no
access was granted.
2. Check Held Door to trigger the door
alarm output if the door is held open
longer than the Held Open Time.
3. Select Energized or De-energized for the Default State of the Door Status Alarm Output.
4. Select an Output to use for the Door Status Alarm Output.
5. Click to enable an Alarm Shunt output to operate when access is granted to the secured door.
6. Select Energized or De-energized for the Default State of the Alarm Shunt Output.
7. Select an Output to use for the Alarm Shunt Output.
Threat Level
1. Select the highest Threat Level
allowed before the door will
automatically lock.
» NOTE: An unlocked door will lock if the System Threat Level is greater than the Door Threat Level; including doors that are unlocked by
schedule.
» NOTE: The Dashboard M-Unlock and E-Unlock may be used to unlock a door that has been locked due to elevated system Threat Level.
2. Check Ignore REX to ignore input from a Rex button if the current System Threat Level is higher than the Door Threat Level.
Anti-Passback
1. Check to enable Timed Anti
Passback. Select a time in seconds to
disable a credential after it has been
used to grant access.
2. Check to enable Room Anti Passback. Select a time in seconds to disable access to a room after access has been granted
to the room.