Notes:
1. The relay activation time is fixed at 7 seconds.
2. If a door contact is used, it is connected to the DC pin of the BioRead Door
Controller.
3. The Door Contact will ensure that the Relay Activation Time is stopped.
4. The BioRead Door Controller turns the RIGHT LED of the BioRead reader
GREEN to indicate relay activation. The LEFT LED on the BioRead turns
GREEN after a valid fingerprint authentication.
5. Relay can switch up to 2A@24VDC. Do not switch high current/voltage
through this relay.
ee Operator Instructions for programming BioRead with the Hand-Held Programmer.
p/n 6035000 rev 2.0 Page 9 of 22