Owner's Manual
BioRead 1000 Series
Installation Manual
Mounting the Reader:
The BioRead Reader mounts on a single-gang electrical box.
1. Remove the screw from the bottom of the unit using a Phillips screwdriver.
2. Remove back mounting plate by pulling gently from inside the cable feed-through hole.
3. Insert the cable from the wall through the hole in the back plate, and then mount the back plate
to the electrical box with the supplied screws.
4. Remove the plug-in connector from the unit and connect the cable as per wiring instructions on
next page.
5. Plug the connector back into the unit.
IMPORTANT: Confirm wiring before applying power as 12VDC applied to wrong pin
can damage the unit.
6. Attach the main unit to the back plate by tilting the bottom of the unit toward you, then sliding
the top of the unit over the back plate.
7. Secure the main unit to the back plate with the screw removed in Step 1.
LED and BEEPER control:
The LED line is used to control the LED on the right side of the unit. This LED is normally RED and will
turn GREEN when the line is pulled LOW.
p/n 6035000 rev 2.0 Page 4 of 22
The BEEPER line is used to activate the unit’s internal beeper. The beeper will sound if the line is pulled
LOW.