Owner's Manual

4 of 17
POWER UNIT INSTALLATION
ILLUSTRATION ABOVE SHOWS A TYPICAL AIR VAC UNIT
Model Exhaust
Side
ABCDFG
H
IJ
AV2500 R 14 16 2.8 4 8 23 24 38 18
AV3500 R 14 16 2.8 4 8 23 24 38 18
AV4500 R 14 16 2.8 4 8 23 24 38 18
AV5500 R 14 16 2.8 4 8 23 24 38 18
FX2000 L 14 16 8.9 4 7 4 28 30 18
FX3000 L 14 16 8.9 4 7 4 28 30 18
FX900 L 14168.947 4 283018
ZX5800 L 14 16 8.9 4 7 4 28 31 18
ZX6000 L 14 16 8.9 4 7 4 28 31 18
ZX7000 L 14 16 8.9 4 7 4 28 31 18
ZX8000 L 14 16 8.9 4 7 4 28 31 18
Note: Dimensions above are in inches
5 of 17
Figure 1
POWER UNIT INSTALLATION
1.0 POWER UNIT LOCATION AND CONNECTION
The Vacuum System Power Unit is normally placed in the garage
(best location), utility room, or basement. Attic locations should be
avoided (A) if canister is difficult for the user to service, (B) where
temperature exceeds 140 degrees. The Power Unit should be located
out of traffic while still accessible for emptying of dirt canister.
2.0 POWER UNIT MOUNTING
For the AV series vacuum the top of the power unit must be a
minimum of 18" from the ceiling and 18" from the corner walls. For the
FX/ZX series the bottom of the power unit must be a minimum of 18"
from the floor and 18" from the corner walls. This clearance is
necessary to allow adequate air flow to cool motors. If exhaust is
used, refer to Figure 1.