Owner's Manual
CONNECT RELAY OUTPUTS CONNECT LOOP INPUTS CONNECT AC POWER
CONNECT BACKUP BATTERY TEST RELAYS TEST LOOPS
WIRING DIAGRAM
TEST SYSTEM LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and
workmanship for twenty four (24) months. The Warranty Expiration
Date is labeled on the product. This warranty extends only to
wholesale customers who buy direct from Linear or through Linear’s
normal distribution channels. Linear does not warrant this product
to consumers. Consumers should inquire from their selling dealer as
to the nature of the dealer’s warranty, if any. There are no obligations
or liabilities on the part of Linear LLC for consequential damages
arising out of or in connection with use or performance of this
product or other indirect damages with respect to loss of property,
revenue, or profit, or cost of removal, installation, or reinstallation.
All implied warranties, including implied warranties for merchantability and
implied warranties for fitness, are valid only until Warranty Expiration Date
as labeled on the product. This Linear LLC Warranty is in lieu of all
other warranties express or implied.
All products returned for warranty service require a Return Product
Authorization Number (RPA#). Contact Linear Technical Service at 1-800-
421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an
important need in portable wireless signalling. However, there are some
limitations which must be observed.
• For U.S. installations only: The radios are required to comply with FCC
Rules and Regulations as Part 15 devices. As such, they have limited
transmitter power and therefore limited range.
• A receiver cannot respond to more than one transmitted signal at a
time and may be blocked by radio signals that occur on or near their
operating frequencies, regardless of code settings.
• Changes or modifications to the device may void FCC compliance.
• Infrequently used radio links should be tested regularly to protect
against undetected interference or fault.
• A general knowledge of radio and its vagaries should be gained prior
to acting as a wholesale distributor or dealer, and these facts should be
communicated to the ultimate users.
Copyright © 2004 Linear LLC 218307 B
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,AM-MIO - LINEAR P/N: 218307 B - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - SCALE: 1-1 - SIDE 2 OF 2
N.O.
1
COM
2
N.C.
3
N.O.
4
CO
M
5
N.C.
6
N.O.
7
CO
M
8
N.C.
9
N.O.
10
COM
11
N.C.
12
N.O.
13
COM
14
N.C.
15
N.O.
16
COM
17
N.C.
18
CHANNEL 1 CHANNEL 2 CHANNEL 3
CHANNEL 4 CHANNEL 5 CHANNEL
6
CONNECT RELAY
OUTPUTS TO TH
E
CONTROLLED
DEVICE
S
RELAY RATING
:
5 AMPS
@
14 VD
C
MAXIMU
M
LOOP
1
1
CO
M
2
LOOP
2
3
LOOP
3
4
CO
M
5
LOOP
4
6
LOOP
5
7
CO
M
8
LOOP
6
9
LOOP
7
10
CO
M
11
LOOP
8
12
2.2K 2.2K 2.2K 2.2K
2.2K 2.2K 2.2K 2.2K
CONNECT ANY INPUTS TO THE
LOOP INPUT TERMINAL
S
EACH LOOP INPUT CAN BE
TRIGGERED WITH A NORMALLY
OPEN OR NORMALLY CLOSED
SWITCH
ALL LOOP INPUTS MUST BE
TERMINATED WITH A 2.2K
END-OF-LINE RESISTOR
EXAMPLE OF LOOPS 1-4
WITH NORMALLY
CLOSED SWITCHE
S
EXAMPLE OF LOOPS 5-
8
WITH NORMALLY
OPEN SWITCHE
S
AC
IN
1
AC
IN
2
EART
H
GND
3
DATA
GN
D
4
POWER
TERMINAL
S
16 VAC, 24 VA MIN.
POWE
R
TRANSFORME
R
UNIFIED
EARTH
GROUND
CONNECT 16 VAC
POWER FROM PLUG-I
N
TRANSFORMER TO
POWER TERMINAL
S
1 &
2
CONNECT A GOOD
EARTH GROUND TO
POWER TERMINAL
3
NOTE: DATA GROUND
TERMINAL IS USED ONLY
WHEN CONNECTING
TO THE CONTROLLE
R
THROUGH TH
E
CONTROLLER AUXILIARY
PBUS TERMINALS
PLACE THE BACKUP
BATTERY IN THE CABINE
T
CONNECT THE RED LEAD TO BATTERY POSITIVE (+)
CONNECT THE BLACK LEAD TO BATTERY NEGATIVE (-)
PRESS THE RELAY
TRIGGER BUTTONS
TO TEST EACH RELA
Y
CONNECTED
THE RELAY STATUS
INDICATOR WILL
LIGHT WHEN TH
E
RELAY IS ENERGIZED
CAUTION!
DEVICES CONNECTED TO
THE RELAYS WILL ACTIVATE
WATCH THE LOOP
STATUS INDICATO
R
WHILE TESTING THE LOOP
S
GREEN = ALL LOOPS NORMAL
RED = ANY LOOP OPEN OR SHORTE
D
LOOP
1
COM LOO
P
2
LOOP
3
COM LOOP
4
2.2K 2.2K
2.2K 2.2K
4
5
6
1
2
3
LOOP
5
COM LOO
P
6
LOOP
7
COM LOOP
8
2.2K 2.2K
2.2K 2.2K
10
11
12
7
8
9
CHANNEL 2 CHANNEL
3
7
8
9
4
5
6
16
17
18
13
14
15
N.O.
CHANNEL
1
2
3
1
11
12
10
COM N.C. N.O. COM N.C. N.O. COM N.C
.
CHANNEL 5 CHANNEL
6
N.O.
CHANNEL 4
COM N.C. N.O. COM N.C. N.O. COM N.C
.
POWER TERMINALS
AC
IN
AC
IN
EARTH
GND
DATA
GND
DAT1 DAT0 DVAL PCLK
AUXILIARY PBUS TERMINALS
RELAY OUTPUT TERMINAL
S
RELAY OUTPUT TERMINAL
S
LOOP INPUT TERMINAL
S
LOOP INPUT TERMINAL
S
ALL LOOP INPUTS MUST BE
TERMINATED WITH A 2.2K
END-OF-LINE RESISTOR
CONTROLLED DEVICE "4"
CONTROLLED DEVICE "5"
CONTROLLED DEVICE "6"
CONTROLLED DEVICE "1"
CONTROLLED DEVICE "2"
CONTROLLED DEVICE "3"
16 VAC, 24 VA
MINIMU
M
TRANSFORMER
EARTH
GROUND
STAKE
CONTROLLER PBUS TERMINALS
6
7
8
5
4
3
2
1
POWER SUPPLY
MODULE (PSM
)
RELAY/LOOP
MODULE (RLM)
AM-MIO RLM WIRING DIAGRAM
AM-MIO PSM WIRING DIAGRAM
12 VDC
BACKUP
BATTERY
+ RED WIRE
- BLACK WIRE
NOTE: OPTIONAL AM-MIO PSM TO CONTROLLER WIRING
SHOWN WHEN NOT USING THE INCLUDED CABL
E
1. PROGRAM THE ACCESS
CONTROL SYSTEM. BE
SURE TO PROGRAM TH
E
SYSTEM FOR THE DEVICE
ADDRESS OF EACH OF TH
E
AM-MIO MODULES.
2. USE ENTRY CODES OR
TRANSMITTERS TO TEST
ACTIVATE EACH OF TH
E
AM-MIO OUTPUT
S
3. TEST TO SEE IF EACH OF
THE AM-MIO LOOP INPUTS
(IF USED) ARE RECOGNIZED
BY THE ACCESS CONTRO