PRINTER’S INSTRUCTIONS: INSTR,INSTL,AE-1000 - LINEAR P/N: 220777 C - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH AE-1000 Telephone Entry & Access Control System Installation Instructions USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800) 468-1340 www.linearcorp.
Contents Introduction ........................................................................... 2 Operation............................................................................... 2 Hardware Features ................................................................ 3 Software Highlights ............................................................... 3 Feature Overview ................................................................... 3 Accessory Overview.............................................
Hardware Features Feature Overview ✓ BUILT-IN RADIO RECEIVER Variable gain, high-sensitivity receiver for wireless transmitters ✓ FOUR FORM “C” (N.O. & N.
Accessory Overview PBUS Accessories Several compatible accessories are available to connect to the AE-1000’s three 6-wire communications “PBUS” inputs. Up to six PBUS accessories can be used with each AE-1000 unit.
Component Locations MICROPHONE OPTIONAL CAMERA DISPLAY CABINET LOCK OPTIONAL POSTAL LOCK KEYPAD SPEAKER INSTALLATION NOTE: FOR EASY WIRING, THE UNIT'S TERMINAL BLOCKS CAN BE UN-PLUGGED FROM THE CIRCUIT BOARD CAMERA CONNECTOR TAMPER SWITCH KEYPAD LIGHTING TAMPER SWITCH CONNECTOR MICROPHONE ANTENNA DISPLAY CONNECTOR RECEIVER RANGE KNOB CPU/INTERFACE CONNECTOR TAMPER MAGNET OPTIONAL CAMERA VIDEO CONNECTOR DISPLAY CONTRAST ADJUSTMENT WIEGAND INPUT TERMINALS RELAY TERMINALS SYSTEM RESTART BUTTON PBU
Wiring Diagram THIS WIRING EXAMPLE SHOWS: DOOR ACCESS WITH A DOOR STRIKE ON RELAY CHANNEL "A" DOOR ACCESS WITH A MAGNETIC LOCK ON RELAY CHANNEL "B" GATE ACCESS WITH A GATE OPERATOR ON RELAY CHANNEL "C" (YOUR INSTALLATION MAY VARY) ELECTRIC DOOR STRIKE AE-1000 PBUS DEVICE PWR GND DAT1 DAT0 DVAL PCLK PBUS DEVICE PBUS DEVICE AE-1000 AE-2000 AM-3 PWR GND DAT1 DAT0 DVAL PCLK PWR GND DAT1 DAT0 DVAL PCLK AE-1000 AE-2000 AM-3 AE-1000 AE-2000 AM-3 READER A TERMINALS LED2 HOLD LED1 DAT 1 DAT 0 GND PWR R
Important Mounting Requirements The AE-1000 Telephone Entry System can be installed for public or private use. The mounting requirements will vary depending on the installation. Review the following information before beginning the installation. Mounting Environment Consider the environmental factors at the desired mounting location. The AE-1000 is designed for direct outdoor installations, however, it is preferable to protect the unit from extreme exposure to sun, driving rain, or snow whenever possible.
Entry System Mounting The AE-1000 cabinet is designed to be mounted three ways: • The unit can be mounted directly to a wall or flat surface. • The unit can be mounted recessed into the wall. • The unit can be mounted on a standard gooseneck pedestal. Choose a well lit location near the controlled opening. Wiring access for power, telephone, earth ground, control output must be available to the mounting location.
Entry System Mounting (Continued) Recessed Mounting The cabinet can be mounted recessed using the accessory trim-ring (P/N ACP00909). The trim-ring mounts in the wall and the cabinet attaches to the trim-ring. 1. Identify the location of any studs in the wall. 2. Cut a 16-1/4” high by 13-1/4” wide rectangular hole between studs at the mounting location. 3. Install any additional mounting material required to provide surfaces inside the wall 13-1/4” apart for attaching the trim-ring. 4.
Relay Output Wiring TYPICAL DOOR STRIKE HOOKUP Any of the four relay outputs channels (A-D) can be used to control access devices on doors or gates. RELAY TERMINALS N.C. COM N.O. DS GND RTE ELECTRIC DOOR STRIKE Door or Pedestrian Gate Control 1. Install a low voltage electric door strike or magnetic lock as a locking device for the door or pedestrian gate. 2. Install the power supply or transformer for the locking device. DO NOT POWER THE AE-1000 FROM THIS POWER SUPPLY. 3.
Power, Battery, & Ground Wiring Power Wiring ✦ NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS COMPLETE. TURN MASTER POWER SWITCH OFF BEFORE WIRING. 1. Route two wires between the AE-1000 and the power transformer. • For power wire runs up to 100 feet, use 18 AWG, THHN 600-volt insulated wire. • For power wire runs up to 200 feet, use 16 AWG, THHN 600-volt insulated wire. 2. Connect the wires to the transformer. Connect the other end of the wires to the AE-1000 AC1 & AC2 terminals.
Telephone Wiring For telephone entry and programming, the AE-1000 connects to a standard telephone line. TELEPHONE TERMINALS Important Telephone Wiring Tips EARTH TIP RING • DO NOT ROUTE TELEPHONE AND AC WIRING INSIDE THE SAME CONDUIT. Route all telephone wires inside a dedicated conduit that is at least six inches away from any AC line wiring.
Optional Postal Lock A postal lock can be installed in the AE-1000 Entry System to provide keyed access for the postal service. The AE-1000 case is designed to accept a U.S. Postal Service postal lock. When the postal lock is engaged, the programmed output relay will activate. 2 REMOVE PLATE 1 REMOVE LOCKNUTS Postal Lock Installation 1. Remove the four locknuts that retain the postal lock switch plate (above the speaker on the AE-1000 faceplate). 2.
PBUS Accessories Several accessories (keypads, proximity readers, remote receivers) can be connected to the AE-1000’s three PBUS input/output ports. A typical application for a remote keypad would be to control a second door or gate. Linear’s PBUS devices compatible with the AE-1000 are: • AM-RRR Remote Radio Receiver • AM-RPR Radio Proximity Receiver • AM-KP Exterior Keypad • AM-KPI Interior Keypad • AM-CRI Card Reader Interface 1.
Optional Network Connection Linear’s AE-1000, AE-2000, & AM-3 Access Control Systems can be connected together in a network. A network will allow sharing programming and user information between the systems. Network wiring conforms to 3-wire RS-485 electrical specifications. Units connected in the network can be wired using one unit as a “hub” or by wiring from one unit to the next in “daisy-chain” fashion. See the figures for wiring options. • Use Belden 9925 or Carol C0600 shielded cable or equivalent.
System Adjustments The factory settings are sufficient for most installations. The system can be adjusted to customize the installation. Speaker Volume Adjustment SPEAKER VOLUME ADJUSTMENT LESS MORE If the resident’s voice from the speaker is too loud or not loud enough, the speaker’s volume can be adjusted. 1. Locate the SPEAKER VOLUME adjustment on the CPU circuit board. 2. Make a directory number call to test the speaker volume.
Internal Controls On-board Pushbuttons STATUS/PROGRAM DISPLAY Seven pushbuttons are on the main circuit board. Refer to the figure for the location of each pushbutton. • “UP” BUTTON adds one to the value on the STATUS/PROGRAM display. • “DOWN” BUTTON subtracts one from value on the STATUS/PROGRAM display. • RELAY “A” LATCH press to latch relay “A”, press again to un-latch. • RELAY “B” LATCH press to latch relay “B”, press again to un-latch.
AE-1000 Operation Requesting Access with an Entry Code • Residents have up to 40 seconds to key in their entry code. • Up to eight seconds are allowed between each keystroke. • All digits of the entry code must be entered. Example: If the entry code length is set for four digits, and the code is 0042, the user must enter “0 0 4 2”. • If the wrong key is pressed, pressing the key will reset the keypad. The correct code can then be entered.
Specifications MECHANICAL Case dimensions: ELECTRICAL Voltage: Current: Backup Battery: Outputs: 13” W x 16-1/4” H x 3-1/2” D 16-24 Volts AC or 12-24 Volts DC 1500 mA @ 16 VAC maximum Externally charged 12 Volt DC source Relay Channels A-D Form “C” 3 Amps @ 30 Volts maximum Inputs: Four normally closed door sense inputs Four normally open exit request inputs Two WIEGAND reader inputs Three PBUS inputs Network: Three-wire network RADIO Frequency: Bandwidth: Sensitivity: Encoding: ENVIRONMENTAL Temperature
Troubleshooting System completely dead 1. No power from transformer. Check voltage at transformer terminals. 2. Check voltage at AE-1000 power terminal strip. Buzz on speaker 1. 2. 3. 4. 5. Check for 24 volt AC power shorted to wiring conduit. Check for telephone line shorted to ground. Verify that telephone wires are twisted pair. Verify that the AE-1000 is connected to earth ground. Check 16 VAC voltage at AE-1000 transformer terminals. Buzz on telephone line 1.