Quick Start Manual

INSTALLATIONINSTRUCTION
2. Pull rubber extrusion into retainer
FRABA Inc.
1800EStateStreet,Suite148,HamiltonNJ08609
Phone1-609-750-8705,Fax1-609-750-8703
www.vitector.com,info@vitector.com
IssueDate:27-Aug-2010
3. Plug sensors into rubber adapter
sleeves and push them into the
circular rubber chamber of the
extrusion
5. Wire sensor cables through rubber
extrusion into the junction boxes
6. Use included 30 ft. cable to
interconnect the junction boxes on
both sides of the door
1. Measure required length of safety
edge and cut rubber. Leave about 1
inch space for each bumper on
both sides of the door.
1inch
4. Install the junction box with included
bend protection on the side of the
door, closest to the operator. Mount
2nd junction box on opposite side.
Final Assembly