Owner's Manual

Propped Door Relay
This output is utilized to inform personnel that the door is being held, or propped open, after a
valid entry. To accomplish this, the Xtreme™ programming controller comes equipped with a relay
and an internal timer circuit that is designated for this purpose. The form C relays are rated to han-
dle one (1) amp of current at either 12 volts or 24 volts, type AC or DC, and can turn on or off one
leg of power to a warning device. Warning device not included with IEI equipment.
1. Connect the three conductor harness with the green,
blue, and gray wire to the propped door relay jack as
shown in diagram A.
2. Connect green wire to V+ on sounder.
3. Connect blue wire to V+ from power supply.
4. Connect V- from power supply to V- on sounder.
5. Gray wire is not used.
DIAGRAM A
Xtreme™ CONTROL RELAY BOARD
V-
V+
V+
GREEN (NO)
BLUE (C)
GRAY (NC) NOT USED
Programming the Propped Door Relay
To program how long the door can be propped open
before the alarm is tripped, Program as follows:
**No programming is done at the Xtreme™ keypad.**
1. Enter programming mode. Press 99 # (master code) *
2. Verify that the programmer is in programming mode.
(Yellow light should be flashing slowly.)
To
Power Supply
To incorporate this feature into your system, simply locate one of the five connectors, each one
with three (3) wires, green, blue, and gray, located in the box with the Xtreme™ programming con-
troller. With the controller powered down, unlatch the keypad from the plastic housing and slide the
printed circuit board out of housing, exposing the connectors as shown in Diagram A.
3. Press 44 # (time) # 0 # **, time represents how
long the door may be propped before the relay
energizes. Time must be 10 to 900 seconds
Propped door time must be programmed in inter-
vals of 10 seconds, ie. 10, 30, 60,... up to 900
seconds.
4. Press * to exit program mode, yellow light
should not be flashing.
NOTE: This feature requires that you utilize the
Normally closed door contact (input) per dia-
gram B.
Normally
closed
door contact
white wire
with orange
stripe
white wire
DIAGRAM B.
Propped
Door
Relay
Wiring the Propped Door Relay