4.7 Wiring the Standalone Access Control
Relays
RelaysK2,K3,andK4providethealarmshunt,proppeddoor,and
forced door relays. Use the following steps to wire these relays.
NOTE: You MUST wire a normally closed door switch, as shown
in Figure 6, for these functions to work properly.
1. (Wiring the alarm shunt) Using P1 (K2), connect the blue
wire (common) to common on the door switch. Connect the
green wire (normally open) to the normally closed contact on
the door switch.
2. (Wiring the propped door alarm)UsingP2(K3),connectthe
green wire (normally open) to the positive on the alarm
device.Connectthebluewire(common)tothepositiveon
thepowersupply.Connectthenegativeonthealarmdevice
to the negative on the power supply.
3. (Wiring the forced door alarm)UsingP3(K4),connectthe
green wire (normally open) to the positive on the alarm
device.Connectthebluewire(common)tothepositiveon
thepowersupply.Connectthenegativeonthealarmdevice
to the negative on the power supply.