Owner's Manual
Auxiliary Outputs
The Extremeâ„¢ programming controller comes equipped with 3 auxiliary relay outputs and 3 inter-
nal timer circuits. The outputs can operate from 01-90 seconds, or you can program them to latch in
the energized position until the same code, or another latch code is entered. These outputs maybe
used to turn on or off, or shunt most devices after a valid code entry. The relays are form C relay
and are rated to handle one (1) amp of current at either 12 volts or 24 volts, type AC or DC.
1. Connect the three conductor harness with the green,
blue, and gray wire to the auxiliary output relay jack as
shown in diagram A.
2. Connect green wire to V+ on sounder.
3. Connect blue wire to V+ from power supply.
4. Connect V- from power supply to V- on sounder.
5. Gray wire is not used.
DIAGRAM A
Xtreme
TM
CONTROL RELAY BOARD
V-
V+
V+
GREEN (NO)
BLUE (C)
GRAY (NC) NOT USED
Programming the Auxiliary Outputs
To program how long the output can operate for, Program
as follows:
1. Enter programming mode. Press 99 # (master code) *
Verify controller is in programming. Yellow light should
be flashing slowly.
To
Power Supply
To incorporate this feature into your system, simply locate one of the five connectors, each one with
three (3) wires, green, blue, and gray, located in the box with the Xtreme
TM
programming controller.
With the controller powered down, unlatch the keypad from the plastic housing and slide the printed
circuit board out of housing. With the circuit board out, you may now choose one of the exposed
outputs as shown in Diagram A.
2. Select the output that you want to program.
For output #2, press 12# (relay time)# 0# * *
For output #3, press 13# (relay time)# 0# **
For output #4, press 14# (relay time)# 0# * *
* Relay time must always be represented by
two digits. for 5 seconds (05).
To operate selected output(s) with a user code.
3. Verify that you are still in programming mode.
4. Press 59# (The output you choose: ie 2) #
(user number) # (new code) * (repeat code) *
5. Exit programming mode by pressing the *
user number is where your code is stored in the memory of
the keypad.
door contact
white wire
with orange
stripe
white wire
DIAGRAM B.
Propped
Door
Relay
Wiring the Auxiliary Relays
Example: to a sounder