Owner's Manual

Shunting an Alarm Zone
Arming and Disarming a typical Alarm Control Panel
Basic Access Control with an Magnetic LockBasic Access Control with an Electric Door Strike
Remote Triggering Input
Not Used
Remote Triggering Input
White/Orange
White
Brown
Programming
Switch
Normally Open
Remote Switch
TS 1
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
Electric door strike
( Fail secure )
Transorb
12 or 24 volt AC/DC
power supply
Note: Lock voltage must
match power supply voltage
SW1
OUTPUT
2
OUTPUT
3
OUTPUT
4
OUTPUT
2
OUTPUT
3
OUTPUT
4
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
TS 1
SW1
Remote Triggering Input
Not Used
Remote Triggering Input
White/Orange
White
Brown
Programming
Switch
Transorb
12 or 24 volt AC/DC
power supply
Note: Lock voltage must
match power supply voltage
Magnetic Doorlock
( Fail Safe )
Normally Open
Remote Switch
Remote Triggering Input
Not Used
Remote Triggering Input
White/Orange
White
Brown
Programming
Switch
Normally Open
Remote Switch
TS 1
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
12 or 24 volt AC/DC
power supply
SW1
OUTPUT
2
OUTPUT
3
OUTPUT
4
To Alarm Panel
Closed Circuit
Loop
NO NC
C
NO NC
C
NO NC
C
NO NC
C
NO NC
C
NO NC
C
NO NC
C
NO NC
C
NO NC
C
NO NC
C
NO NC
C
NO NC
C
Programming
Switch
OUTPUT
2
OUTPUT
3
OUTPUT
4
-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC
GREEN LED (-)
RED LED (-)
12 VOLTS (+)
ARM/DISARM
TERMINALS
12 VOLTS (-)
12 VOLTS (+)
TS 1
SW1
TYPICAL ALARM
CONTROL PANEL
Green LED
( panel disarmed )
Red LED
( panel armed )
NOTE: LED’s not provided with Keypad.
Connections are shown for a typical panel with
sink outputs.
6061170 REV 1.01