Datasheet
3
LTK001
001fa
T
A
= 25°C, V
S
= ±15V (Amplifier), V
S
= 5V (Compensator)
LTK001A LTK001
PARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX UNITS
Total Temperature Error at 25°C Type E 0.75 2.5 °C
(Note 3)
Type J 0.75 2.5 °C
Type K, T 0.86 2.5 °C
Type R, S (Note 12) 5.0 5.0 °C
Slope Error (Notes 4 and 9) 0°C ≤ T
J
≤ 70°C Type E 0.05 0.09 °C/°C
Type J 0.06 0.09 °C/°C
Type K, T 0.07 0.10 °C/°C
Type R, S 0.28 0.32 °C/°C
Total Temperature Error at 0°C ≤ T
J
≤ 70°C Type E 2.0 5 °C
Temperature Extremes (Note 9)
Type J 2.1 5 °C
Type K, T 2.6 5.2 °C
Type R, S (Note 12) 16 16 °C
– 55°C ≤ T
J
≤ 125°C Type E 6 8.5 °C
Type J 6 8.5 °C
Type K, T 6.3 9 °C
Type R, S (Note 12) 30 30 °C
Temperature Error Change with 0.1 0.1 °C/V
Supply Voltage (Note 5)
Supply Current 480 900 480 900 µA
ELECTRICAL CHARACTERISTICS
(Matched Amplifier and Compensator)