Datasheet

LTC6803-2/LTC6803-4
23
680324fa
OPERATION
COMMAND DESCRIPTION NAME CODE PEC
Start Cell Voltage ADC Conversions and Poll Status,
with Discharge Permitted
STCVDC All
Cell 1
Cell 2
Cell 3
Cell 4
Cell 5
Cell 6
Cell 7
Cell 8
Cell 9
Cell 10
Cell 11
Cell 12
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
E7
E0
E9
EE
FB
FC
F5
F2
DF
D8
D1
D6
C3
Start Open-Wire ADC Conversions and Poll Status,
with Discharge Permitted
STOWDC All
Cell 1
Cell 2
Cell 3
Cell 4
Cell 5
Cell 6
Cell 7
Cell 8
Cell 9
Cell 10
Cell 11
Cell 12
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
97
90
99
9E
8B
8C
85
82
AF
A8
A1
A6
B3
Table 10. Configuration (CFG) Register Group
REGISTER RD/WR BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0
CFGR0 RD/WR WDT GPIO2 GPIO1 LVLPL CELL10 CDC[2] CDC[1] CDC[0]
CFGR1 RD/WR DCC8 DCC7 DCC6 DCC5 DCC4 DCC3 DCC2 DCC1
CFGR2 RD/WR MC4I MC3I MC2I MC1I DCC12 DCC11 DCC10 DCC9
CFGR3 RD/WR MC12I MC11I MC10I MC9I MC8I MC7I MC6I MC5I
CFGR4 RD/WR VUV[7] VUV[6] VUV[5] VUV[4] VUV[3] VUV[2] VUV[1] VUV[0]
CFGR5 RD/WR VOV[7] VOV[6] VOV[5] VOV[4] VOV[3] VOV[2] VOV[1] VOV[0]
Table 9. Command Codes and PEC Bytes (continued)