APPLICATIONS INFORMATION
Output Filtering
The output voltage, V
OUT
, is simply I
OUT
• Z
OUT
. This
makes fi ltering straightforward. Any circuit may be used
which generates the required Z
OUT
to get the desired fi lter
response. For example, a capacitor in parallel with R
OUT
will give a low pass response. This will reduce unwanted
noise from the output, and may also be useful as a charge
reservoir to keep the output steady while driving a switch-
ing circuit such as a mux or ADC. This output capacitor
in parallel with an output resistor will create a pole in the
output response at:
f
–3dB
=
1
2•π •R
OUT
•C
OUT
Useful Equations
Input Voltage: V
SENSE
= I
SENSE
•R
SENSE
Voltage Gain:
V
OUT
V
SENSE
=
R
OUT
R
IN
Current Gain:
I
OUT
I
SENSE
=
R
SENSE
R
IN
Transconductance:
I
OUT
V
SENSE
=
1
R
IN
Transimpedance:
V
OUT
I
SENSE
= R
SENSE
R
OUT
R
IN
Figure 5. V
+
Powered Separately from
Load Supply (V
BATT
)
Figure 6. LTC6101 Supply Current
Monitored with Load
LTC6101
R
OUT
V
OUT
6101 F05
R
IN
LOAD
V
+
R
SENSE
V
BATTERY
+
V
+
V
OUT
–IN+IN
LTC6101
R
OUT
V
OUT
6101 F06
R
IN
LOAD
V
+
R
SENSE
+
V
+
V
OUT
–IN+IN
Input Common Mode Range
The inputs of the LTC6101 can function from 1.5V below
the positive supply to 0.5V above it. Not only does this
allow a wide V
SENSE
range, it also allows the input refer-
ence to be separate from the positive supply (Figure 5).
Note that the difference between V
BATT
and V
+
must be no
more than the common mode range listed in the Electrical
Characteristics table. If the maximum V
SENSE
is less than
500mV, the LTC6101 may monitor its own supply current,
as well as that of the load (Figure 6).
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.