elecTrical characTerisTics
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: The LTC4412 is tested under pulsed load conditions such that T
J
≈
T
A
. The LTC4412E is guaranteed to meet performance specifications from
0°C to 85°C operating junction temperature range. Specifications over
the –40°C to 85°C operating junction temperature range are assured by
design, characterization and correlation with statistical process controls.
The LTC4412I is guaranteed over the –40°C to 85°C operating junction
temperature range. The LTC4412MP is tested and guaranteed over the
–55°C to 150°C operating junction temperature range. High junction
temperatures degrade operating lifetimes; operating lifetime is degraded
for junction temperatures greater than 125°C. Note that the maximum
ambient temperature consistent with these specifications is determined
by specific operating conditions in conjunction with board layout, the
rated package thermal impedance and other environmental factors. T
J
is calculated from the ambient temperature T
A
and power dissipation P
D
according to the following formula: T
J
= T
A
+ (P
D
• Θ
JA
), where Θ
JA
=
230°C/W for the TSOT-23 package.
Note 3: This results in the same supply current as would be observed with
an external P-channel MOSFET connected to the LTC4412 and operating in
forward regulation.
Note 4: V
IN
is held at 12V and GATE is forced to 10.5V. SENSE is set at
12V to measure the source current at GATE. SENSE is set at 11.9V to
measure sink current at GATE.
Note 5: V
IN
is held at 12V and SENSE is stepped from 12.2V to 11.8V to
trigger the event. GATE voltage is initially V
G(OFF)
.
Note 6: V
IN
is held at 12V and SENSE is stepped from 11.8V to 12.2V to
trigger the event. GATE voltage is initially internally clamped at V
G(ON)
.
Note 7: STAT is forced to V
IN
– 1.5V. SENSE is set at V
IN
– 0.1V to
measure the off current at STAT. SENSE is set V
IN
+ 0.1V to measure the
sink current at STAT.
Note 8: STAT is forced to 9V and V
IN
is held at 12V. SENSE is stepped
from 11.8V to 12.2V to measure the STAT turn-on time defined when I
STAT
reaches one half the measured I
S(SNK).
SENSE is stepped from 12.2V to
11.8V to measure the STAT turn-off time defined when I
STAT
reaches one
half the measured I
S(SNK) .