Datasheet

LTC4222
25
4222fb
APPLICATIONS INFORMATION
Table 3. CONTROL Registers A – Read/Write
BIT CONTROL 1 (D0h) CONTROL 2 (D4h) OPERATION
7:6 GPIO1 Configure GPIO2 Configure
FUNCTION A6 A7 GPIO PIN
Power Good (Default) 0 0 GPIO = C3
Power
Good 0 1 GPIO = C3
General Purpose Output 1 0 GPIO = A5
General Purpose Input 1 1 C6 = GPIO
5 GPIO1 Output GPIO2 Output Output Data for GPIO Pins When Configured as General Purpose Output
1 = High Impedance, 0 = Pulled Low
4 Reserved Mass Write Enable Allows Mass Write Addressing
1 = Mass Write Enabled (Default), 0 = Mass Write Disabled
3 Channel 1 FET On Control Channel 2 FET On Control On Control Bit, Latches the State of the On Pin at the End of the
Debounce Delay
1 = FET On, 0 = FET Off
2 Channel 1 Overcurrent Auto-Retry Channel 2 Overcurrent Auto-Retry Overcurrent Auto-Retry Bit
1 = Auto-Retry After Overcurrent, 0 = Latch Off After Overcurrent
(Default)
1 Channel 1 Undervoltage Auto-Retry Channel 2 Undervoltage Auto-Retry Undervoltage Auto-retry
1 = Auto-Retry After Undervoltage (Default), 0 = Latch Off After
Undervoltage
0 Channel 1 Overvoltage Auto-Retry Channel 2 Overvoltage Auto-Retry Overvoltage Auto-retry
1 = Auto-Retry After Overvoltage (Default), 0 = Latch Off After
Overvoltage
Table 4. ALERT Registers B – Read/Write
BIT ALERT 1 (D1h) ALERT 2 (D5h) OPERATION
7 Reserved Reserved Not Used
6 Reserved Reserved Not Used
5 Channel 1 FET Short Alert Channel 2 FET Short Alert Enables Alert for FET Short Condition
1 = Enable Alert, 0 = Disable Alert (Default)
4 EN1 State Change Alert EN2 State Change Alert Enables Alert When EN Changes State
1 = Enable Alert, 0 = Disable Alert (Default)
3 Channel 1 Power Bad Alert Channel 2 Power Bad Alert Enables Alert When Output Power is Bad
1 = Enable Alert, 0 = Disable Alert (Default)
2 Channel 1 Overcurrent Alert Channel 2 Overcurrent Alert Enables Alert for Overcurrent Condition
1 = Enable Alert, 0 = Disable Alert (Default)
1 Channel 1 Undervoltage Alert Channel 2 Undervoltage Alert Enables Alert for Undervoltage Condition
1 = Enable Alert, 0 = Disable Alert (Default)
0 Channel 1 Overvoltage Alert Channel 2 Overvoltage Alert Enables Alert for Overvoltage Condition
1 = Enable Alert, 0 = Disable Alert (Default)