operaTion
voltage between CSP and BAT to a representative current.
Error amp CA2 compares this current against the desired
current programmed by the I
DAC
at the I
DC
pin and adjusts
I
TH
for the desired voltage across R
SENSE
.
The voltage at BAT is divided down by an internal resis-
tor divider
set by the V
DAC
and is used by error amp EA
to decrease I
TH
if the divider voltage is above the 1.19V
reference.
The amplifier CL1 monitors and limits the input current,
normally from the AC adapter, to a preset level (100mV/
R
CL
). At input current limit, CL1 will decrease the I
TH
volt-
age to reduce charging current.
An
overvoltage comparator, OV, guards against transient
overshoots (>7%). In this case, the top MOSFET is turned
off until the overvoltage condition is cleared. This feature
is useful for batteries that “load dump” themselves by
opening their protection switch to perform functions such
as calibration or pulse mode charging.
PWM Watchdog Timer
There is a watchdog timer that observes the activity on
the TGATE pin. If TGATE stops switching for more than
40µs, the watchdog activates and turns off the top MOSFET
for about 400ns. The watchdog engages
to prevent very
low
frequency operation in dropout—a potential source
of audible noise when using ceramic input and output
capacitors.
Charger Start-Up
When
the charger is enabled, it will not begin switching
until the I
TH
voltage exceeds a threshold that assures initial
current will be positive. This threshold is 5% to 15% of the
maximum programmed current. After the charger begins
switching, the various loops will control the current at a
level that is higher or lower than the initial current. The
duration of this transient condition depends upon the loop
compensation, but is typically less than 1ms.
SMBus Interface
All communications over the SMBus are interpreted by the
SMBus interface block. The SMBus interface is a SMBus
slave device at address 0x12. All internal LTC4100 registers
may be updated and accessed through the SMBus interface,
and charger controller as required. The SMBus protocol is
a derivative of the I
2
C bus (Reference
I
2
C-Bus and How to
Use It, V1.0
by Philips, and
System Management Bus Speci-
fication
, Version 1.1, from the SBS Implementers Forum, for
a complete description of the bus protocol requirements).
All data is clocked into the shift register on the rising
edge of
SCL. All data is clocked out of the shift register
on
the falling edge of SCL. Detection of an SMBus Stop
condition, or power-on reset via the V
DD
power-fail, will
reset the SMBus interface to an initial state at any time.
The LTC4100 command set is interpreted by the SMBus
interface and passed onto the charger controller block as
control signals or updates to internal registers.
Figure 3
t
OFF
OFF
OFF
ON
ON
TGATE
BGATE
INDUCTOR
CURRENT
TRIP POINT SET
BY I
TH
VOLTAGE
4100 F03
*http://www.SBS-FORUM.org