Datasheet

LTC3883/LTC3883-1
94
3883fa
For more information www.linear.com/LTC3883
Only bits 7, 6 and 4 are supported in the LTC3883.
The user is permitted to write a 1 to any bit in this command to clear a specific fault. This permits the user to clear
status by means other than using the CLEAR_FAULTS command.
Any supported fault bit in this command will initiate an ALERT event.
This command has one data byte.
STATUS_CML
The STATUS_CML commands returns one byte with the status information on received commands and system
memory/logic.
Bit 2 of this command is not supported in the LTC3883.
If either bit 3 or bit 4 of this command is set, a serious and significant internal error has been detected. Continued
operation of the part is not recommended if these bits are continuously set.
The user is permitted to write a 1 to any bit in this command to clear a specific fault. This permits the user to clear
status by means other than using the CLEAR_FAULTS command.
Any supported fault bit in this command will initiate an ALERT event.
This command has one data byte.
STATUS_MFR_SPECIFIC
The STATUS_MFR_SPECIFIC commands returns one byte with the manufacturer specific status information.
The format for this byte is:
BIT MEANING
7 Internal Temperature Fault Limit Exceeded.
6 Internal Temperature Warn Limit Exceeded.
5 Factory Trim Area NVM CRC Fault.
4 PLL is Unlocked
3 Fault Log Present
2 V
DD33
UV or OV Fault
0 GPIO Pin Asserted Low by External Device
If any of these bits are set, the MFR bit in the STATUS_WORD will be set.
The user is permitted to write a 1 to any bit in this command to clear a specific fault. This permits the user to clear
status by means other than using the CLEAR_FAULTS command. Exception: The fault log present bit can only be
cleared by issuing the MFR_FAULT_LOG_CLEAR command.
Any supported fault bit in this command will initiate an ALERT event.
This command has one data byte.
PMBus
COMMAND DETAILS