Datasheet

LTC3883/LTC3883-1
77
3883fa
For more information www.linear.com/LTC3883
PMBus
COMMAND DETAILS
IOUT_OC_FAULT_LIMIT
The IOUT_OC_FAULT_LIMIT command sets the value of the peak output current limit, in amperes. When the controller
is in current limit, the overcurrent detector will indicate an overcurrent fault condition. The programmed overcurrent
fault limit value is rounded up to the nearest one of the following set of discrete values:
25mV/IOUT_CAL_GAIN Low Range (1.5x Nominal Loop Gain)
MFR_PWM_MODE_LT C 3883 [7]=0
28.6mV/IOUT_CAL_GAIN
32.1mV/IOUT_CAL_GAIN
35.7mV/IOUT_CAL_GAIN
39.3mV/IOUT_CAL_GAIN
42.9mV/IOUT_CAL_GAIN
46.4mV/IOUT_CAL_GAIN
50mV/IOUT_CAL_GAIN
37.5mV/IOUT_CAL_GAIN High Range (Nominal Loop Gain)
MFR_PWM_MODE_LT C 3883 [7]=1
42.9mV/IOUT_CAL_GAIN
48.2mV/IOUT_CAL_GAIN
53.6mV/IOUT_CAL_GAIN
58.9mV/IOUT_CAL_GAIN
64.3mV/IOUT_CAL_GAIN
69.6mV/IOUT_CAL_GAIN
75mV/IOUT_CAL_GAIN
Note: This is the peak of the current waveform. The READ_IOUT command returns the average current. The peak output
current limits are adjusted with temperature based on the MFR_IOUT_CAL_GAIN_TC using the equation:
Peak Current Limit = IOUT_CAL_GAIN • (1 + MFR_IOUT_CAL_GAIN_TC • (READ_TEMPERTURE_1-27.0)).
The LTpowerPlay GUI automatically convert the voltages to currents.
The I
OUT
range is set with bit 7 of the MFR_PWM_MODE_LT C 3883 command.
The IOUT_OC_FAULT_LIMIT is ignored during TON_RISE and TOFF_FALL.
This command has two data bytes and is formatted in Linear_5s_11s format.
IOUT_OC_WARN_LIMIT
This command sets the value of the output current that causes an
output overcurrent warning in amperes. The
READ_IOUT value will be used to determine if this limit has been exceeded.
In response to the IOUT_OC_WARN_LIMIT being exceeded, the device:
Sets the NONE_OF_THE_ABOVE bit in the STATUS_BYTE
Sets the IOUT bit in the STATUS_WORD
Sets the IOUT Overcurrent Warning bit in the STATUS_IOUT command, and
Notifies the host by asserting ALERT pin
This condition is detected by the ADC so the response time may be up to 120ms.
The IOUT_OC_FAULT_LIMIT is ignored during TON_RISE and TOFF_FALL.
This command has two data bytes and is formatted in Linear_5s_11s format.