PMBUS
COMMANDS
The following tables list supported PMBus commands and
manufacturer specific commands. A complete description
of these commands can be found in thePMBus Power
System Mgt Protocol SpecificationPart IIRevision
1.1”. Users are encouraged to reference this specification.
Exceptions or manufacturer specific implementations
are listed below in Table 2. Floating point values listed in
theDEFAULT VALUE” column are either Linear 16-bit
Signed (PMBus Section 8.3.1) or Linear_5s_11s (PMBus
Section 7.1) format, whichever is appropriate for the com
-
mand. All
commands from 0xD0 through 0xFF not listed
in
this table are implicitly reserved by the manufacturer.
Users should avoid blind writes within this range of com
-
mands to avoid undesired operation of the part. All com-
mands from 0
x00 through 0xCF not listed in this table are
implicitly not supported by the manufacturer. Attempting to
access non-supported or reserved commands may result
in a CML command fault event. All output voltage settings
and measurements are based on the VOUT_MODE setting
of 0x14. This translates to an exponent of 2
–12
.
If PMBus commands are received faster than they are be-
ing processed
,
the part may become too busy to handle
new commands. In these circumstances the part follows
the
protocols defined in the PMBus Specification v1.1,
PartII, Section 10.8.7, to communicate that it is busy.
The part includes handshaking features to eliminate busy
errors and simplify error handling software while ensur
-
ing robust
communication and system behavior. Please
refer
to the subsection titled PMBus Communication and
Command Processing in the Applications Information
section for further details.
COMMAND NAME
CMD
CODE DESCRIPTION TYPE
DATA
FORMAT UNITS NVM
DEFAULT
VALUE PAGE
PAGE 0x00 Provides integration with multi-page PMBus
devices.
R/W Byte Reg 0x00
64
OPERATION 0x01 Operating mode control. On/off, margin high and
margin low.
R/W Byte Reg Y 0x80
67
ON_OFF_CONFIG 0x02 RUN pin and PMBus bus on/off command
configuration.
R/W Byte Reg Y 0x1E
66
CLEAR_FAULTS 0x03 Clear any fault bits that have been set. Send Byte NA
92
WRITE_PROTECT 0x10 Level of protection provided by the device
against accidental changes.
R/W Byte Reg Y 0x00
64
STORE_USER_ALL 0x15 Store user operating memory to EEPROM. Send Byte NA
100
RESTORE_USER_ALL 0x16 Restore user operating memory from EEPROM. Send Byte NA
100
CAPABILITY 0x19 Summary of PMBus optional communication
protocols supported by this device.
R Byte Reg 0xB0
91
VOUT_MODE 0x20 Output voltage format and exponent (2
–12
). R Byte
Reg
2
–12
0x14
71
VOUT_COMMAND 0x21 Nominal output voltage set point. R/W Word L16 V Y 1.0
0x1000
73
VOUT_MAX 0x24 Upper limit on the output voltage the unit can
command regardless of any other commands.
R/W Word L16 V Y 5.5
0x5800
72
VOUT_MARGIN_HIGH 0x25 Margin high output voltage set point. Must be
greater than VOUT_COMMAND.
R/W Word L16 V Y 1.05
0x10CD
72
VOUT_MARGIN_LOW 0x26 Margin low output voltage set point. Must be
less than VOUT_COMMAND.
R/W Word L16 V Y 0.95
0x0F33
73
VOUT_TRANSITION_RATE 0X27 Rate the output changes when VOUT
commanded to a new value.
R/W Word L11 V/ms Y 0.25
AA00
80
FREQUENCY_SWITCH 0x33 Switching frequency of the controller. R/W Word L11 kHz Y 350
0xFABC
70
Table 2. Summary (Note: The Data Format abbreviations are detailed at the end of this table.)
PMBus
COMMAND SUMMARY