Datasheet

LTC3883/LTC3883-1
103
3883fa
For more information www.linear.com/LTC3883
MFR_READ_ICHIP [7:0] 44
STATUS_MFR_SPECIFIC BYTE 45
Reserved BYTE 46 Always returns 0x00.
EVENT n-1
(data measured before fault was detected)
READ_VOUT [15:8] LIN 16 47
[7:0] 48
Reserved BYTE 49 Always returns 0x00.
Reserved BYTE 50 Always returns 0x00.
READ_IOUT [15:8] LIN 11 51
[7:0] 52
MFR_READ_IIN_CHAN [15:8] LIN 11 53
[7:0] 54
READ_VIN [15:8] LIN 11 55
[7:0] 56
READ_IIN [15:8] LIN 11 57
[7:0] 58
STATUS_VOUT BYTE 59
Reserved BYTE 60 Always returns 0x00.
STATUS_WORD [15:8] WORD 61
[7:0] 62
Reserved BYTE 63 Always returns 0x00.
Reserved BYTE 64 Always returns 0x00.
STATUS_MFR_SPECIFIC BYTE 65
Reserved BYTE 66 Always returns 0x00.
*
*
*
EVENT n-5
(Oldest Recorded Data)
READ_VOUT [15:8] LIN 16 127
[7:0] 128
Reserved BYTE 129 Always returns 0x00.
Reserved BYTE 130 Always returns 0x00.
READ_IOUT [15:8] LIN 11 131
[7:0] 132
MFR_READ_IIN_CHAN [15:8] LIN 11 133
[7:0] 134
READ_VIN [15:8] LIN 11 135
[7:0] 136
READ_IIN [15:8] LIN 11 137
[7:0] 138
STATUS_VOUT BYTE 139
Reserved BYTE 140 Always returns 0x00.
STATUS_WORD [15:8] WORD 141
[7:0] 142
Reserved BYTE 143 Always returns 0x00.
PMBus
COMMAND DETAILS