Datasheet

LTC3883/LTC3883-1
102
3883fa
For more information www.linear.com/LTC3883
MFR_REAL_TIME [7:0] BYTE 1 48 bit binary counter. The value is the time since the last reset in 200µs
increments.
[15:8] BYTE 2
[23:16] BYTE 3
[31:24] BYTE 4
[39:32] BYTE 5
[47:40] BYTE 6
MFR_VOUT_PEAK [15:8] LIN 16 7 Peak READ_VOUT since last MFR_CLEAR_PEAKS command.
[7:0] 8
Reserved BYTE 9
Reserved BYTE 10
MFR_IOUT_PEAK [15:8] LIN 11 11 Peak READ_IOUT since last MFR_CLEAR_PEAKS command.
[7:0] 12
MFR_READ_IIN_CHAN_PEAK [15:8] LIN 11 13 Peak READ_IIN since last MFR_CLEAR_PEAKS command.
[7:0] 14
MFR_VIN_PEAK [15:8] LIN 11 15 Peak READ_VIN since last MFR_CLEAR_PEAKS command.
[7:0] 16
READ_TEMPERATURE_1 [15:8] LIN 11 17 External temperature during last event.
[7:0] 18
Reserved BYTE 19 Always returns 0x00.
Reserved BYTE 20 Always returns 0x00.
READ_TEMPERATURE_2 [15:8] LIN 11 21 Internal temperature sensor during last event
[7:0] 22
MFR_TEMPERATURE_1_PEAK [15:8] LIN 11 23 Peak READ_TEMPERATURE_1 since last MFR_CLEAR_PEAKS
command.
[7:0] 24
Reserved BYTE 25 Always returns 0x00.
Reserved BYTE 26 Always returns 0x00.
CYCLICAL DATA
EVENT n
(Data at Which Fault Occurred; Most Recent Data)
Event “n” represents one complete cycle of ADC reads through the MUX
at time of fault. Example: If the fault occurs when the ADC is processing
step 15, it will continue to take readings through step 25 and then store
the header and all 6 event pages to
EEPROM
READ_VOUT [15:8]
LIN 16 27
[7:0] 28
Reserved BYTE 29 Always returns 0x00.
Reserved BYTE 30 Always returns 0x00.
READ_IOUT [15:8] LIN 11 31
[7:0] 32
MFR_READ_IIN_CHAN [15:8] LIN 11 33
[7:0] 34
READ_VIN [15:8] LIN 11 35
[7:0] 36
READ_IIN [15:8] LIN 11 37
[7:0] 38
STATUS_VOUT BYTE 39
Reserved BYTE 40 Always returns 0x00.
STATUS_WORD [15:8] WORD 41
[7:0] 42
MFR_READ_ICHIP [15:8] WORD 43
PMBus
COMMAND DETAILS