Datasheet
LTC3880/LTC3880-1
97
3880fc
For more information www.linear.com/LTC3880
PMBus
COMMAND DETAILS
MFR_PADS
This command provides the user a means of directly reading the digital status of the I/O pins of the device. The bit
assignments of this command are as follows:
BIT ASSIGNED DIGITAL PIN
15 V
DD33
OV Fault
14 V
DD33
UV Fault
13 Reserved
12 Reserved
11 ADC Values Invalid, Occurs
During Start-Up
10 Device Driving ALERT Low
9 PowerGood1
8 PowerGood0
7 Device Driving RUN1 Low
6 Device Driving RUN0 Low
5 RUN1
4 RUN0
3 Device Driving GPIO1 Low
2 Device Driving GPIO0 Low
1 GPIO1
0 GPIO0
A 1 indicates the condition is true.
This read-only command has two data bytes.
MFR_COMMON
The MFR_COMMON command contains bits that are common to all LTC digital power and telemetry products.
BIT MEANING
7 CHIP NOT DRIVING ALERT LOW
6 CHIP NOT BUSY
5 CALCULATIONS NOT PENDING
4 OUTPUT NOT IN TRANSITION
3 NVM Initialized
2 Reserved
1 SHARE_CLK Timeout
0 WP Pin Status
This read-only command has one data byte.