Datasheet

LTC3880/LTC3880-1
104
3880fc
For more information www.linear.com/LTC3880
CYCLICAL DATA
EVENT n
(Data at Which Fault Occurred; Most Recent Data)
Event “n” represents one complete cycle of ADC reads through the MUX
at time of fault. Example: If the fault occurs when the ADC is processing
step 15, it will continue to take readings through step 25 and then store
the header and all 6 event pages to EEPROM
READ_VOUT (PAGE 0) [15:8] LIN 16 27
[7:0] LIN 16 28
READ_VOUT (PAGE 1) [15:8] LIN 16 29
[7:0] LIN 16 30
READ_IOUT (PAGE 0) [15:8] LIN 11 31
[7:0] LIN 11 32
READ_IOUT (PAGE 1) [15:8] LIN 11 33
[7:0] LIN 11 34
READ_VIN [15:8] LIN 11 35
[7:0] LIN 11 36
READ_IIN [15:8] LIN 11 37
[7:0] LIN 11 38
STATUS_VOUT (PAGE 0) BYTE 39
STATUS_VOUT (PAGE 1) BYTE 40
STATUS_WORD (PAGE 0) [15:8] WORD 41
[7:0] WORD 42
STATUS_WORD (PAGE 1) [15:8] WORD 43
[7:0] WORD 44
STATUS_MFR_SPECIFIC (PAGE 0) BYTE 45
STATUS_MFR_SPECIFIC (PAGE 1) BYTE 46
PMBus
COMMAND DETAILS