Datasheet
LTC3868
15
3868fd
Figure 3. RMS Input Current Comparison
meaning that the actual power wasted is reduced by a fac-
tor of 2.66. The reduced input ripple voltage also means
less power is lost in the input power path, which could
include batteries, switches, trace/connector resistances
and protection circuitry. Improvements in both conducted
and radiated EMI also directly accrue as a result of the
reduced RMS input current and voltage.
Of course, the improvement afforded by 2-phase opera-
tion is a function of the dual switching regulator’s relative
duty cycles which, in turn, are dependent upon the input
voltage V
IN
(Duty Cycle = V
OUT
/V
IN
). Figure 3 shows how
the RMS input current varies for single phase and 2-phase
operation for 3.3V and 5V regulators over a wide input
voltage range.
It can readily be seen that the advantages of 2-phase op-
eration are not just limited to a narrow operating range,
for most applications is that 2-phase operation will reduce
the input capacitor requirement to that for just one channel
operating at maximum current and 50% duty cycle.
OPERATION
(Refer to the Functional Diagram)
INPUT VOLTAGE (V)
0
INPUT RMS CURRENT (A)
3.0
2.5
2.0
1.5
1.0
0.5
0
10 20 30 40
3868 F03
SINGLE PHASE
DUAL CONTROLLER
2-PHASE
DUAL CONTROLLER
V
O1
= 5V/3A
V
O2
= 3.3V/3A