OPERATION
REG NAME B[7] B[6] B[5] B[4] B[3] B[2] B[1] B[0] DEFAULT
0x01 BUCK1 Enable:
0 = Disabled if
EN_B1 Low
1 = Enabled
Mode:
00 = Pulse-Skipping
01 = Burst
10 = Forced Continuous
Start-Up:
0 =
Enable at
Any
Output
Voltage
1 = Enable
Only if Output
<300mV
Phase Select:
0 = Clock
Phase 1
1 = Clock
Phase 2
Clock Rate:
0 = 2.25MHz
1 = 1.125MHz
Keep
Alive
Buck1:
0 = Do Not
Keep Alive
1= Keep Alive in
Shutdown.
Switch DV/DT
Control:
0 = Slow
1 = Fast
0000 0000
0x02
BUCK2 Enable:
0 = Disabled if
EN_B2
Low
1 = Enabled
Mode:
00 = Pulse-Skipping
01 = Burst
10 = Forced Continuous
Start-Up:
0 =
Enable at
Any
Output
Voltage
1 = Enable
Only if Output
<300mV
Phase Select:
0 = Clock
Phase 1
1 = Clock
Phase 2
Clock Rate:
0 = 2.25MHz
1 = 1.125MHz
Keep
Alive
Buck2:
0 = Do Not
Keep Alive
1 = Keep Alive
in Shutdown
Switch DV/DT
Control:
0 = Slow
1 = Fast
0000 0000
0x03
BUCK3 Enable:
0 = Disabled if
EN_B3
Low
1 = Enabled
Mode:
00 = Pulse-Skipping
01 = Burst
10 = Forced Continuous
Start-Up:
0 =
Enable at
Any
Output
Voltage
1 = Enable
Only if Output
<300mV
Phase Select:
0 = Clock
Phase 1
1 = Clock
Phase 2
Clock Rate:
0 = 2.25MHz
1 = 1.125MHz
Keep
Alive
Buck3:
0 = Do Not
Keep Alive
1 = Keep Alive
in Shutdown
Switch DV/DT
Control:
0 = Slow
1 = Fast
0000 0000
0x04
BUCK4 Enable:
0 = Disabled if
EN_B4
Low
1 = Enabled
Mode:
00 = Pulse-Skipping
01 = Burst
10 = Forced Continuous
Start-Up:
0 =
Enable at
Any
Output
Voltage
1 = Enable
Only if Output
<300mV
Phase Select:
0 = Clock
Phase 1
1 = Clock
Phase 2
Clock Rate:
0 = 2.25MHz
1 = 1.125MHz
Keep
Alive
Buck4:
0 = Do Not
Keep Alive
1 = Keep Alive
in Shutdown
Switch DV/DT
Control:
0 = Slow
1 = Fast
0000 0000
0x05
LDOA Reserved Reserved Enable LDO3:
0 = Disabled if
EN_L3
Low
1 = Enabled
Start-Up LDO3:
0 = Enable at
Any Output
Voltage
1 = Enable
Only if Output
<300mV
Keep Alive
LDO3:
0 = Do Not
Keep
Alive
1 = Keep Alive
in Shutdown.
Enable LDO2:
0 = Disabled if
EN_L2
Low
1 = Enabled
Start-Up LDO2:
0 = Enable at
Any Output
Voltage
1 = Enable
Only if Output
<300mV
Keep Alive
LDO2:
0 = Do Not
Keep
Alive
1 = Keep Alive
in Shutdown
XX00 0000
0x06 LDOB Reserved Reserved Reserved LTC3676-1 LDO4 Output
Voltage:
00 = 1.2V
01 = 2.5V
10 = 2.8V
11 = 3.0V
Enable
LDO4:
0 = Disabled if
EN_L4
Low
1 = Enabled
Start-Up LDO4:
0 = Enable at
Any Output
Voltage
1 = Enable
Only if Output
<300mV
Keep Alive
LDO4:
0 = Do Not
Keep
Alive
1 = Keep Alive
in Shutdown
XX00 0000
0x07 SQD1 Sequence Down Buck4:
00 = With WAKE
01 =
WAKE + 100ms
10 = WAKE + 200ms
11 = WAKE + 300ms
Sequence
Down Buck3:
00 = With WAKE
01 =
WAKE + 100ms
10 = WAKE + 200ms
11 = WAKE + 300ms
Sequence
Down Buck2:
00 = With WAKE
01 =
WAKE + 100ms
10 = WAKE + 200ms
11 = WAKE + 300ms
Sequence
Down Buck1:
00 = With WAKE
01 =
WAKE + 100ms
10 = WAKE + 200ms
11 = WAKE + 300ms
0000 0000
Table 21. LTC3676 Command Registers