Datasheet

LTC3589/LTC3589-1/
LTC3589-2
8
3589ff
For more information www.linear.com/3589
Note 1: Stresses beyond those listed Under Absolute Maximum ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum rating condition for extended periods may affect device
reliability and lifetime.
Note 2: The LTC3589 are tested under pulsed load conditions such
that T
J
≈ T
A
. The LTC3589E are guaranteed to meet specifications from
0°C to 85°C junction temperature. Specifications over the –40°C to
125°C operating junction temperature range are assured by design,
characterization and correlation with statistical process controls. The
LTC3589I are guaranteed over the –40°C to 125°C operating junction
temperature range and the LTC3589H are guaranteed over the full –40°C to
150°C operating junction temperature range. High junction temperatures
degrade operating lifetimes; operating lifetime is derated for junction
temperatures greater than 125°C. The junction temperature (T
J
in °C) is
calculated from the ambient temperature (T
A
in °C) and power dissipation
(PD, in Watts) according to the formula:
T
J
= T
A
+ (PD • θ
JA
), where the package junction to ambient thermal
impedance θ
JA
= 33°C/W.
Note that the maximum ambient temperature consistent with these
specifications is determined by specific operating conditions in
conjunction with board layout, the rated package thermal impedance and
other environmental factors.
Note 3: The LTC3589 include overtemperature protection that is intended
to protect the device during momentary overload conditions. Junction
temperature will exceed 150°C when overtemperature protection is active.
Continuous operation above the specified maximum operating temperature
may impair device reliability.
Note 4: Dropout voltage is defined as (V
IN
– V
LDO
) for LDO1 or
(V
IN_LDO
– V
LDO
) for other LDOs when V
LDO
is 3% lower than V
LDO
measured with V
IN
= V
IN_LDO
= 4.3V.
Note 5: Dynamic supply current is higher due to the gate charge being
delivered at the switching frequency.
Note 6: Soft-start measured in test mode with regulator error amplifier in
unity gain mode.
elecTrical characTerisTics
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
V
RSTO
RSTO Output Low Voltage I
RSTO
= 3mA 0.1 0.4 V
I
RSTO
RSTO Output High Leakage Current V
RSTO
= 3.8V –0.1 0.1 µA
V
IRQ
IRQ Output Low Voltage I
IRQ
= 3mA 0.1 0.4 V
I
IRQ
IRQ Output High Leakage Current V
IRQ
= 3.8V –0.1 0.1 µA
The l denotes the specifications which apply over the specified operating
junction temperature range, otherwise specifications are at T
A
= 25°C (Note 2). V
IN
= PV
IN1
= PV
IN2
= PV
IN3
= PV
IN4
= V
IN_LDO2
= V
IN_LDO34
= DV
DD
= 3.8V. All regulators disabled unless otherwise noted.