Datasheet

LTC3589/LTC3589-1/
LTC3589-2
38
3589ff
For more information www.linear.com/3589
operaTion
Table 17. LTC3589 Command Register Table
REG NAME B[7] B[6] B[5] B[4] B[3] B[2] B[1] B[0] DEFAULT
0x07 SCR1 Buck-Boost
Mode:
0 = Continuous
1 = Burst Mode
Step-Down Switching
Regulator 3 Mode :
0 0 = Pulse-Skipping
0 1 = Burst
1 0 = Forced Continuous
Step-Down Switching
Regulator 2 Mode :
0 0 = Pulse-Skipping
0 1 = Burst
1 0 = Forced Continuous
Step-Down Switching
Regulator 1 Mode :
0 0 = Pulse-Skipping
0 1 = Burst
1 0 = Forced Continuous
0000 0000
0x10 OVEN Software
Control Mode:
0 = Enable
with Pin or
OVEN Register
1 = Enable/
Disable with
OVEN Register
Only
EN_LDO4 EN_LDO3 EN_LDO2 EN4 EN3 EN2 EN1 0000 0000
0x12
LTC3589
SCR2 Mask PGOOD
Hard
Shutdown:
0 = Allow
PGOOD
Timeout Hard
Shutdown.
1 = Inhibit
PGOOD Hard
Shutdown.
LDO4
Start-Up:
0 = Wait for
Output < 300mV
Before Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
LDO3
Start-Up:
0 = Wait
for Output
< 300mV
Before Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
LDO2
Start-Up:
0 = Wait for
Output <
300mV Before
Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
Buck-Boost
Start-Up:
0 = Wait
for Output
< 300mV
Before Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
Step-Down
Switching
Regulator 3
Start-Up:
0 = Wait
for Output
< 300mV
Before Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
Step-Down
Switching
Regulator 2
Start-Up:
0 = Wait
for Output
< 300mV Before
Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
Step-Down
Switching
Regulator 1
Start-Up:
0 = Wait
for Output
< 300mV
Before Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
0000 0000
0x12
LTC3589-1
SCR2 Mask PGOOD
Hard
Shutdown:
0 = Inhibit
PGOOD
Timeout Hard
Shutdown.
1 = Allow
PGOOD Hard
Shutdown.
LDO4
Start-Up:
0 = Wait for
Output < 300mV
Before Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
LDO3
Start-Up:
0 = Wait
for Output
< 300mV
Before Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
LDO2
Start-Up:
0 = Wait for
Output <
300mV Before
Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
Buck-Boost
Start-Up:
0 = Wait
for Output
< 300mV
Before Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
Step-Down
Switching
Regulator 3
Start-Up:
0 = Wait
for Output
< 300mV
Before Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
Step-Down
Switching
Regulator 2
Start-Up:
0 = Wait
for Output
< 300mV Before
Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
Step-Down
Switching
Regulator 1
Start-Up:
0 = Wait
for Output
< 300mV
Before Enable
1 = Don’t Wait
and Disable
Discharge
Resistor.
0000 0000