Datasheet

LTC3200/LTC3200-5
2
V
IN
to GND...................................................0.3V to 6V
V
OUT
to GND .............................................0.3V to 5.5V
V
FB
, SHDN to GND........................ 0.3V to (V
IN
+ 0.3V)
I
OUT
(Note 2)....................................................... 150mA
ORDER PART
NUMBER
MS8 PART MARKING
T
JMAX
= 150°C, θ
JA
= 230°C/W
Consult factory for parts specified with wider operating temperature ranges.
LTNV
LTC3200EMS8
ABSOLUTE AXI U RATI GS
W
WW
U
PACKAGE/ORDER I FOR ATIO
UUW
(Note 1)
ELECTRICAL CHARACTERISTICS
The denotes specifications which apply over the full operating
temperature range. Specifications are at T
A
= 25°C, V
IN
= 3.6V, C
FLY
= 1µF, C
IN
= 1µF, C
OUT
= 1µF unless otherwise noted.
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
V
IN
Input Voltage 2.7 4.5 V
V
OUT
Output Voltage 2.7V V
IN
4.5V, I
OUT
40mA 4.8 5 5.2 V
3.1V V
IN
4.5V, I
OUT
100mA 4.8 5 5.2 V
I
CC
Operating Supply Current I
OUT
= 0mA, SHDN = V
IN
3.5 8 mA
I
SHDN
Shutdown Current SHDN = 0V, V
OUT
= 0V 1 µA
V
FB
FB Voltage (LTC3200) 1.217 1.268 1.319 V
I
FB
FB Input Current (LTC3200) V
FB
= 1.4V –50 50 nA
V
R
Output Ripple (LTC3200-5) V
IN
= 3V, I
OUT
= 100mA 30 mV
P-P
η Efficiency (LTC3200-5) V
IN
= 3V, I
OUT
= 50mA 80 %
F
OSC
Switching Frequency 1 2 MHz
V
IH
SHDN Input Threshold 1.3 V
V
IL
SHDN Input Threshold 0.4 V
I
IH
SHDN Input Current SHDN = V
IN
–1 1 µA
I
IL
SHDN Input Current SHDN = 0V –1 1 µA
t
ON
V
OUT
Turn-On Time V
IN
= 3V, I
OUT
= 0mA, 10% to 90% 0.8 ms
R
OL
Open-Loop Output Resistance V
IN
= 3V, I
OUT
= 100mA, V
FB
= 0V (Note 4) 9.2
V
OUT
1
GND 2
SHDN 3
6 C
+
5 V
IN
4 C
TOP VIEW
S6 PACKAGE
6-LEAD PLASTIC SOT-23
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: Based on long term current density limitations.
Note 3: The LTC3200E/LTC3200E-5 are guaranteed to meet performance
specifications from 0°C to 70°C. Specifications over the –40°C to 85°C
operating temperature range are assured by design, characterization and
correlation with statistical process controls.
Note 4: R
OL
(2 V
IN
– V
OUT
)/I
OUT
V
OUT
Short-Circuit Duration ............................. Indefinite
Operating Temperature Range (Note 3) .. 40°C to 85°C
Storage Temperature Range ................. 65°C to 150°C
Lead Temperature (Soldering, 10 sec)..................300°C
ORDER PART
NUMBER
S6 PART MARKING
LTSH
LTC3200ES6-5
1
2
3
4
C
+
V
IN
C
PGND
8
7
6
5
V
OUT
FB
SHDN
SGND
TOP VIEW
MS8 PACKAGE
8-LEAD PLASTIC MSOP
T
JMAX
= 150°C, θ
JA
= 200°C/W