Datasheet
LTC3115-1
36
31151fb
For more information www.linear.com/LTC3115-1
Typical applicaTions
24V 750kHz Industrial Rail Restorer
Regulated Output Voltage from a
Time Varying Input Rail 0A to 1.5A Load Step, V
IN
= 20V
Efficiency vs Load Current
BST1 BST2
PV
IN
V
IN
RUN
PV
OUT
VC
FB
RT
PV
CC
V
CC
PWM/SYNC
SW1 SW2
GND PGND
LTC3115-1
L1
22µH
C
BST1
0.1µF
C
BST2
0.1µF
20V TO 40V
OPEN
DRAIN
OUTPUT
C
FF
47pF
C1
4.7µF
24V
1.5A
C
IN
10µF
C
O
82µF
1µF
*
R
TOP
1M
R
BOT
43.2k
R
T
47.5k
C
O
: OS-CON 35SVPF82M
L1: TOKO 892NBS-220M
*OPTIONAL: INSTALL IN
APPLICATIONS SUBJECT TO
OUTPUT OVERLOAD OR
SHORT-CIRCUIT CONDITIONS
31151 TA05a
R
FF
51k
R
FB
25k
C
FB
3300pF
100pF
R1
500k
+
ON OFF
V
IN
(5V/DIV)
V
OUT
(5V/DIV)
10ms/DIV
31151 TA05b
40V
20V
LOAD
CURRENT
(1A/DIV)
INDUCTOR
CURRENT
(2A/DIV)
V
OUT
(1V/DIV)
500µs/DIV
31151 TA05c
LOAD CURRENT (A)
0.01
60
EFFICIENCY (%)
80
100
0.10 1
31151 TA05d
40
50
70
90
30
20
V
IN
= 20V
V
IN
= 24V
V
IN
= 36V
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.