Datasheet
LTC2990
16
Rev. F
For more information www.analog.com
APPLICATIONS INFORMATION
Table4. STATUS Register (Default 0x00)
BIT NAME OPERATION
b7 0 Always Zero
b6 V
CC
Ready 1 = V
CC
Register Contains New Data, 0 = V
CC
Register Read
b5 V4 Ready 1 = V4 Register Contains New Data, 0 = V4 Register Read
b4 V3, T
R2
, V3 – V4 Ready 1 = V3 Register Contains New Data, 0 = V3 Register Data Old
b3 V2 Ready 1 = V2 Register Contains New Data, 0 = V2 Register Data Old
b2 V1, T
R1
, V1 – V2 Ready 1 = V1 Register Contains New Data, 0 = V1 Register Data Old
b1 T
INT
Ready 1 = T
INT
Register Contains New Data, 0 = T
INT
Register Data Old
b0 Busy* 1= Conversion In Process, 0 = Acquisition Cycle Complete
*In Repeat mode, Busy = 1 always
Table5. CONTROL Register (Default 0x00)
BIT NAME OPERATION
b7 Temperature Format Temperature Reported In; Celsius = 0 (Default), Kelvin = 1
b6 Repeat/Single Repeated Acquisition = 0 (Default), Single Acquisition = 1
b5 Reserved Reserved
b[4:3] Mode [4:3] Mode Description
0 0 Internal Temperature Only (Default)
0 1 T
R1
, V1 or V1 – V2 Only per Mode [2:0]
1 0 T
R2
, V3 or V3 – V4 Only per Mode [2:0]
1 1 All Measurements per Mode [2:0]
b[2:0] Mode [2:0] Mode Description
0 0 0 V1, V2, T
R2
(Default)
0 0 1 V1 – V2, T
R2
0 1 0 V1 – V2, V3, V4
0 1 1 T
R1
, V3, V4
1 0 0 T
R1
, V3 – V4
1 0 1 T
R1
, T
R2
1 1 0 V1 – V2, V3 – V4
1 1 1 V1, V2, V3, V4
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.