Datasheet
LTC2978A
62
2978afa
For more information www.linear.com/LTC2978A
BYTE
NUMBER
DECIMAL
BYTE
NUMBER
HEX
LOOP
BYTE
NUMBER
DECIMAL
DATA LOOP 4
40 BY
TES PER
LOOP
212 D4
4 Read_vout1[7:0]
213 D5 3 Status_mfr0
214 D6 2 Status_vout0
215 D7 1 Read_vout0[15:8]
216 D8 0 Read_vout0[7:0]
BYTE
NUMBER
DECIMAL
BYTE
NUMBER
HEX
LOOP
BYTE
NUMBER
DECIMAL
DATA
LOOP 5
40 BY
TES PER
LOOP
217 D9
39 Status_mfr7
218 DA 38 Status_vout7
219 DB 37 Read_vout7[15:8]
220 DC 36 Read_vout7[7:0]
221 DD 35 Status_mfr6
222 DE 34 Status_vout6
223 DF 33 Read_vout6[15:8]
224 E0 32 Read_vout6[7:0]
225 E1 31 Status_mfr5
226 E2 30 Status_vout5
227 E3 29 Read_vout5[15:8]
228 E4 28 Read_vout5[7:0]
229 E5 27 Status_mfr4
230 E6 26 Status_vout4
231 E7 25 Read_vout4[15:8]
232 E8 24 Read_vout4[7:0]
233 E9 23 Reserved
234 EA 22 Status_temp
235 EB 21 Read_
temperature_1[15:8]
236 EC 20 Read_
temperature_1[7:0]
237 ED 19 Status_mfr3 Last Valid Fault
Log Byte
RESERVED BYTES
238 EE 0x00 Bytes EE - FE
Return 0x00 But
Must Be Read
239 EF 0x00
240 F0 0x00
241 F1 0x00
242 F2 0x00
243 F3 0x00
244 F4 0x00
245 F5 0x00
246 F6 0x00
247 F7 0x00
248 F8 0x00
249 F9 0x00
250 FA 0x00
251 FB 0x00
252 FC 0x00
253 FD 0x00
254 FE 0x00
Use One Block
Read Command
to Read 255
Bytes Total,
from 0x00 to
0xFE
PMBus
COMMAND DESCRIPTION