Datasheet

LTC2974
16
2974fc
For more information www.linear.com/LTC2974
operaTion
LTC2974 OPERATION OVERVIEW
The LTC2974 is a PMBus programmable power supply
controller, monitor, sequencer and voltage and current
supervisor that can perform the following operations:
Accept PMBus compatible programming commands.
Provide DC/DC converter input voltage, output voltage,
output current, output temperature, and internal junction
temperature readback through the PMBus interface.
Control the output of DC/DC converters that set the
output voltage with a trim pin or DC/DC converters
that set the output voltage using an external resistor
feedback network.
Sequence the startup of DC/DC converters via PMBus
programming and the CONTROL input pins. The LTC
2974 supports time-based sequencing and tracking
sequencing. Cascade sequence on with time based
sequence off is also supported.
Trim the DC/DC converter output voltage (typically in
0.02% steps), in closed-loop servo operating mode,
autonomously or through PMBus programming.
Margin the DC/DC converter output voltage to PMBus
programmed limits.
Trim or margin the DC/DC converter output voltage with
direct access to the margin DAC.
Supervise the DC/DC converter input voltage, output
voltage, load current and the inductor temperatures
for overvalue/undervalue conditions with respect to
PMBus programmed limits and generate appropriate
faults and warnings.
Accurately handle inductor self-heating transients using
a proprietary algorithm. These self-heating effects are
combined with external temperature sensor readings
to improve accuracy of current supervisors and ADC
current measurement.
Respond to a fault condition by continuing operation
indefinitely, latching-off after a programmable deglitch
period, latching-off immediately or sequencing off
after TOFF_DELAY. Use retry mode to automatically
recover from a latched-off condition. With retry enabled,
MFR_RETRY_COUNT programs the number of retries
(0 to 6 or infinite) for all pages.
Optionally stop trimming the DC/DC converter output
voltage after it reaches the initial margin or nominal
target. Optionally allow servo to resume if target drifts
outside of V
OUT
warning limits.
Store command register contents with CRC to EEPROM
through PMBus programming.
Restore EEPROM contents through PMBus program
-
ming or when VDD33 is applied on power-up.
Report the DC/DC converter output voltage status
through the power good output.
Generate interrupt requests by asserting the ALERTB pin
in response to supported PMBus faults and warnings.
Coordinate system wide fault responses for all DC/DC
converters connected to the LTC2974 FAULTB0 and
FAULTB1 pins.
Synchronize sequencing delays or shutdown for multiple
devices using the SHARE_CLK pin.
Software and hardware write protect the command
registers.
Disable the input voltage to the supervised DC/DC
converters in response to output OV, UV, OC and UC
faults.
Log telemetry and status data to EEPROM in response
to a faulted-off condition.
Supervise an external microcontrollers activity for a
stalled condition with a programmable watchdog timer
and reset it if necessary.
Prevent a DC/DC converter from re-entering the on
state after a power cycle until a programmable interval
(MFR_RESTART_DELAY) has elapsed and its output
has decayed below a programmable threshold voltage
(MFR_VOUT_DISCHARGE_THRESHOLD).
Record minimum and maximum observed values of
input voltage, output voltages, output currents and
output temperatures.
Access user EEPROM data directly, without alter
-
ing RAM space (Mfr_ee_unlock, Mfr_ee_erase, and
Mfr_ee_data).
Facilitates
in-house
bulk
programming.