Datasheet
LTC2495
28
2495fd
Figure 21. Input Normal Mode Rejection at f
S
= 256 • f
N
Figure 20. Input Normal Mode Rejection at DC
applications inForMation
Figure 22. Input Normal Mode Rejection vs Input Frequency with
Input Perturbation of 100% (60Hz Notch)
Figure 23. Input Normal Mode Rejection vs Input Frequency with
Input Perturbation of 100% (50Hz Notch)
INPUT SIGNAL FREQUENCY (Hz)
INPUT NORMAL MODE REJECTION (dB)
2495 F20
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
–120
f
N
0 2f
N
3f
N
4f
N
5f
N
6f
N
7f
N
8f
N
f
N
= f
EOSC/5120
INPUT SIGNAL FREQUENCY (Hz)
250f
N
252f
N
254f
N
256f
N
258f
N
260f
N
262f
N
INPUT NORMAL MODE REJECTION (dB)
2495 F21
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
–120
f
N
= f
EOSC/5120
INPUT FREQUENCY (Hz)
0 15 30 45 60 75 90 105 120 135 150 165 180 195 210 225 240
NORMAL MODE REJECTION (dB)
2495 F23
0
–20
–40
–60
–80
–100
–120
V
CC
= 5V
V
REF
= 5V
V
IN(CM)
= 2.5V
V
IN(P-P)
= 5V
T
A
= 25°C
MEASURED DATA
CALCULATED DATA
INPUT FREQUENCY (Hz)
0 12.5 25 37.5 50 62.5 75 87.5 100 112.5 125 137.5 150 162.5 175 187.5 200
NORMAL MODE REJECTION (dB)
2495 F24
0
–20
–40
–60
–80
–100
–120
V
CC
= 5V
V
REF
= 5V
V
IN(CM)
= 2.5V
V
IN(P-P)
= 5V
T
A
= 25°C
MEASURED DATA
CALCULATED DATA