Datasheet

LTC1864/LTC1865
7
18645fb
TIMING CHARACTERISTICS
The denotes specifi cations which apply over the full operating temperature
range, otherwise specifi cations are T
A
= 25°C. V
CC
= 5V, V
REF
= 5V, f
SCK
= f
SCK(MAX)
as defi ned in Recommended Operating Conditions,
unless otherwise noted.
LTC1864/LTC1865
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
t
CONV
Conversion Time (See Figure 1)
H-Grade
2.75
2.75
3.2
3.3
μs
μs
f
SMPL(MAX)
Maximum Sampling Frequency
H-Grade
250
234
kHz
kHz
t
dDO
Delay Time, SCK to SDO Data Valid C
LOAD
= 20pF
C
LOAD
= 20pF
C
LOAD
= 20pF, H-Grade
15 20
25
30
ns
ns
ns
t
dis
Delay Time, CONV to SDO Hi-Z
H-Grade
30
30
60
65
ns
ns
t
en
Delay Time, CONV to SDO Enabled C
LOAD
= 20pF
C
LOAD
= 20pF, H-Grade
30
30
60
65
ns
ns
t
hDO
Time Output Data Remains Valid After SCK C
LOAD
= 20pF
510 ns
t
r
SDO Rise Time C
LOAD
= 20pF 8 ns
t
f
SDO Fall Time C
LOAD
= 20pF 4 ns
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: All voltage values are with respect to GND.
Note 3: Integral nonlinearity is defi ned as deviation of a code from a
straight line passing through the actual endpoints of the transfer curve.
The deviation is measured from the center of the quantization band.
Note 4: Channel leakage current is measured while the part is in sample
mode.