Datasheet

12
LTC1759
OPERATIO
U
Table 1: Supported Charger Functions
SMBus ADDRESS COMMAND CODE
FUNCTION (7-BIT) (8-BIT hex) ACCESS DATA TYPE
ChargerSpecInfo() b0001_001 h11 r Register
ChargerMode() b0001_001 h12 w Register
ChargerStatus() b0001_001 h13 r Register
ChargingCurrent() b0001_001 h14 w Register
ChargingVoltage() b0001_001 h15 w Register
AlarmWarning() b0001_001 h16 w Control
LTCVersionFunction() b0001_001 h3c r Register
OptionalMfgFunction3() b0001_001 h3d Not Supported
OptionalMfgFunction2() b0001_001 h3e Not Supported
OptionalMfgFunction1() b0001_001 h3f Not Supported
Alert Response Address
1
b0001_100 N/A Read Byte Interrupt Address
1
Read-byte format. 89h is returned as the interrupt address of the LTC1759. Rev 1.0 SMBus Compliant.
Table 2: SMBus Word Bit Definitions for All Allowed LTC1759 Functions
POWER-ON
WORD BIT RESET VALUE
FUNCTION FIELD MAPPING (BINARY) ALLOWED VALUES
ChargerSpecInfo CHARGER_SPEC 3:0 0001 The CHARGER_SPEC Reports the Version of the Smart Battery
Charger Specification the Charger Supports
0001 – Version 1.0
All Other Codes Reserved
Always Returns 0001
Read Only. Write Will NACK
SELECTOR_SUPPORT 4 0 0 – Charger Does Not Support the Optional Smart Battery Selector
Commands
1 – Charger Supports the Optional Smart Battery Selector
Commands
Always Returns 0
Read Only. Write Will NACK
Reserved 15:5 0 These Bits Are Reserved and Must Return Zero
Read Only. Write Will NACK
ChargerMode() INHIBIT_CHARGE 0 0 0 – Enable Charging (Power-On Default)
1 – Inhibit Charging
Write Only. Read Will NACK
Cleared to Power-On Reset Value When:
1) POR_RESET = 1
2) AC_PRESENT = 0
3) BATTERY_PRESENT = 0
ENABLE_POLLING 1 0 • 0 – Disable Polling (Power-On Default for Smart Battery Controlled
Chargers)
• 1 – Enable Polling (Power-On Default for Host Controlled Chargers).
• Ignored by LTC1759
Write Only. Read Will NACK
POR_RESET 2 0 0 – Mode Unchanged (Default)
1 – Set Charger to Power-On Defaults
This Reset Only Affects the Charger_Controller Block
Write Only. Read Will NACK