Datasheet

3
LTC1421/LTC1421-2.5
Note 3: After power-on reset, the V
OUTLO
and V
OUTHI
have to drop below the
V
TRIP
point before the charge pump is restarted.
Note 4: After power-on reset, the V
OUTLO
has to drop below the V
TRIP
point
before the charge pump is restarted.
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: All currents into device pins are positive; all currents out of device
pins are negative. All voltages are reference to ground unless otherwise
specified.
ELECTRICAL CHARACTERISTICS
The denotes specifications which apply over the full operating
temperature range, otherwise specifications are at T
A
= 25°C. V
CCHI
= 12V, V
CCLO
= 5V unless otherwise noted (Note 2).
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
I
RAMP
RAMP Pin Output Current Charge Pump On, V
RAMP
= 0.4V 11 17 23 µA
I
CP
Charge Pump Output Current Charge Pump On, GATEHI = 0V 600 µA
GATELO = 0V 300 µA
V
GATEHI
GATEHI N-Channel Gate Drive V
GATEHI
V
OUTHI
616V
V
GATELO
GATELO N-Channel Gate Drive V
GATELO
V
OUTLO
10 16 V
V
AUXVCC
Auxiliary V
CC
Output Voltage V
CCLO
= 5V, Unloaded 4.5 V
V
IL
Input Low Voltage CON1, CON2, POR 0.8 V
V
IH
Input High Voltage CON1, CON2, POR 2V
I
IN
Input Current CON1, CON2, POR = GND –30 –60 –90 µA
V
OL
Output Low Voltage RESET, COMPOUT, PWRGD, DISABLE, FAULT, 0.4 V
I
O
= 3mA
CPON, I
O
= 3mA 1.45 V
V
OH
Output High Voltage DISABLE, I
O
= –3mA 4V
CPON, I
O
= –1mA 3.4 V
I
PU
Logic Output Pull-Up Current RESET, PWRGD, FAULT = GND 15 µA
AC CHARACTERISTICS
t
1
CON1 or CON2to CPON Figure 1, C
L
= 15pF 15 20 30 ms
t
2
PWRGDto RESET Figure 1, R
L
= 10k to V
CCLO
, C
L
= 15pF 160 200 240 ms
140 200 280 ms
t
3
PWRGDto DISABLE Figure 1, C
L
= 15pF 160 200 240 ms
140 200 280 ms
t
4
PORto CPON Figure 1, C
L
= 15pF 15 20 30 ms
t
5
PWRGDto RESET Figure 1, R
L
= 10k to V
CCLO
, C
L
= 15pF 32 µs
t
6
PORto CPON Figure 1, C
L
= 15pF 50 ns
t
7
CON1 or CON2to CPON Figure 1, C
L
= 15pF 50 ns
t
9
Short-Circuit Detect to FAULT Figure 1, R
L
= 10k to V
CCLO
, C
L
= 15pF 20 µs
V
CCLO
– SETLO = 0mV to 100mV
t
10
Short-Circuit Detect to CPON Figure 2, C
L
= 15pF 20 µs
V
CCLO
– SETLO = 0mV to 100mV
t
11
PORto FAULT Figure 2, R
L
= 10k to V
CCLO
, C
L
= 15pF 20 ns
t
CHL
Comparator High to Low COMP
= 1.232V, 10mV Overdrive 0.25 0.5 µs
R
L
= 10k to V
CCLO
, C
L
= 15pF
t
CLH
Comparator Low to High COMP
= 1.232V, 10mV Overdrive 1 1.5 µs
R
L
= 10k to V
CCLO
, C
L
= 15pF