Datasheet
14
LTC1410
Figure 14. Mode 1a. CONVST Starts a Conversion. Data Outputs Always Enabled
(CONVST = )
Figure 15. Mode 1b. CONVST Starts a Conversion. Data Outputs Always Enabled
(CONVST = )
DATA (N – 1)
DB11 TO DB0
CONVST
BUSY
1410 F15
t
CONV
t
6
t
13
t
7
CS = RD = 0
DATA N
DB11 TO DB0
DATA (N + 1)
DB11 TO DB0
DATA
t
5
t
6
t
8
CONVST
BUSY
1410 F16
t
5
t
CONV
t
8
t
13
t
6
t
9
t
12
DATA N
DB11 TO DB0
t
11
t
10
RD
DATA
Figure 16. Mode 2. CONVST Starts a Conversion. Data is Read by RD
APPLICATIONS INFORMATION
WUU
U
DATA N
DB11 TO DB0
DATA (N + 1)
DB11 TO DB0
DATA (N – 1)
DB11 TO DB0
CONVST
CS = RD = 0
BUSY
1410 F14
t
5
t
CONV
t
6
t
8
t
7
DATA