SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
V
IH
High Level Input Voltage V
DD
= 5.25V 2.4 V
V
IL
Low Level Input Voltage V
DD
= 4.95V 0.8 V
I
IN
Digital Input Current V
IN
= 0V to V
DD
±10 µA
C
IN
Digital Input Capacitance 5pF
V
OH
High Level Output Voltage V
DD
= 4.95V
I
O
= –10µA 4.7 V
I
O
= –200µA 4.0 V
V
OL
Low Level Output Voltage V
DD
= 4.95V
I
O
= 160µA 0.05 V
I
O
= 1.6mA 0.10 0.4 V
I
OZ
High Z Output Leakage D11-D0/8 V
OUT
= 0V to V
DD
, CS High ±10 µA
C
OZ
High Z Output Capacitance D11-D0/8 CS High (Note 9 ) 15 pF
I
SOURCE
Output Source Current V
OUT
= 0V 10 mA
I
SINK
Output Sink Current V
OUT
= V
DD
10 mA
DIGITAL I PUTS A D DIGITAL OUTPUTS
UU
The denotes the specifications which apply over the
full operating temperature range, otherwise specfications are at T
A
= 25°C. (Note 5)
LTC1273A/LTC1275A/LTC1276A
LTC1273B/LTC1275B/LTC1276B
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
V
DD
Positive Supply Voltage LTC1273/LTC1276 (Notes 10, 11) 4.95 5.25 V
LTC1275 (Note 10) 4.75 5.25 V
V
SS
Negative Supply Voltage LTC1275 (Note 10) 2.45 5.25 V
LTC1276 (Notes 10, 11) 4.95 5.25 V
I
DD
Positive Supply Current 15 25 mA
I
SS
Negative Supply Current LTC1275/LTC1276 0.065 0.200 mA
P
D
Power Dissipation 75 mW
POWER REQUIRE E TS
W
U
The denotes the specifications which apply over the full operating temperature
range, otherwise specfications are at T
A
= 25°C. (Note 5)
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
f
SAMPLE(MAX)
Maximum Sampling Frequency (Note 10)
Commercial
300 kHz
Military 250 kHz
t
CONV
Conversion Time Commercial 2.7 µs
Military 3.0 µs
t
1
CS to RD Setup Time 0ns
t
2
RD to BUSY Delay C
L
= 50pF 80 190 ns
Commercial
230 ns
Military 270 ns
TI I G CHARACTERISTICS
W
U
LTC1273A/LTC1275A/LTC1276A
LTC1273B/LTC1275B/LTC1276B
The denotes the specifications which apply over the full operating temperature
range, otherwise specfications are at T
A
= 25°C. See Timing Characteristics Figures (Note 5)