Datasheet

LT6110
4
6110fa
For more information www.linear.com/LT6110
Typical perForMance characTerisTics
V
OS
Temperature Coefficient V
OS
vs IOUT Voltage V
OS
vs IOUT Voltage
V
OS
Distribution V
OS
vs Supply Voltage V
OS
vs Supply Voltage
SUPPLY VOLTAGE (V)
0
INPUT OFFSET VOLTAGE (µV)
400
300
200
0
100
–100
–200
10 205 15 30
6110 G02
40
25 35
T
A
= 0°C
T
A
= 25°C
T
A
= 85°C
T
A
= 125°C
T
A
= –40°C, –55°C
I
+IN
= 100µA
V
IOUT
= 0.4V
V
IMON
= 0V
SUPPLY VOLTAGE (V)
35
INPUT OFFSET VOLTAGE (µV)
400
300
200
0
100
–100
–200
40
6110 G03
50
45
T
A
= 25°C
T
A
= 0°C
T
A
= 125°C
T
A
= –40°C, –55°C
I
+IN
= 100µA
V
IOUT
= 25V
V
IMON
= 0V
T
A
= 85°C
IOUT VOLTAGE (V)
0.1
INPUT OFFSET VOLTAGE (µV)
400
300
200
0
100
–100
–200
1
6110 G05
40
10
T
A
= 0°C
T
A
= 25°C
T
A
= 125°C
T
A
= –55°C
V
+
= 36V
V
IMON
= 0V
I
+IN
= 100µA
T
A
= –40°C
T
A
= 85°C
IOUT VOLTAGE (V)
30
INPUT OFFSET VOLTAGE (mV)
10
5
6
7
8
9
4
2
3
1
0
35
6110 G06
50
4540
T
A
= 25°C
T
A
= 0°C
T
A
= 125°C
T
A
= –55°C
V
+
= 50V
V
IMON
= 25V
I
+IN
= 100µA
T
A
= 85°C
T
A
= –40°C
INPUT OFFSET VOLTAGE TEMPERATURE COEFFICIENT (µV/°C)
–3.0
NUMBER OF UNITS
12
8
4
10
6
2
0
–1.0 1.0–2.0 0 2.0
6110 G04
3.0
40 UNITS
–40°C TO 125°C
V
+
= 5V
V
IOUT
= 1.2V
V
IMON
= 0V
I
+IN
= 100µA
INPUT OFFSET VOLTAGE (µV)
–350
NUMBER OF UNITS
200
175
100
150
50
75
125
25
0
–150 –50 15050–250 250
6110 G01
350
800 UNITSV
+
= 5V
V
IOUT
= 1.2V
V
IMON
= 0V
I
+IN
= 100µA
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime. In addition to the Absolute Maximum Ratings, the
output current and supply current must be limited to insure that the power
dissipation in the LT6110 does not allow the die temperature to exceed
150°C. See the Applications Information section Power Dissipation for
further information.
Note 2: R
SENSE
resistance and maximum R
SENSE
currents are guaranteed
by characterization and process controls.
Note 3: The LT6110I is guaranteed to meet specified performance from
–40°C to 85°C. The LT6110H is guaranteed to meet specified performance
from –40°C to 125°C.
Note 4: Specified error is for the LT6110 output current mirror and does
not include errors due to V
OS
or resistor tolerances. Since most systems
will not have 100% correction, the total system error can be compensated
to less than the specified error with proper design. See the Applications
Information section for details.
Note 5: Measurement errors limit automatic testing accuracy. These
measurements are guaranteed by design correlation, characterization and
testing to wider limits.
Note 6: The 0°C ≤ T
A
≤ 85°C temperature range is guaranteed by
characterization and correlation to testing at–40°C, 25°C and 85°C.
elecTrical characTerisTics